0
Parameter static.auto_provision.local_log.backup.append.limit_mode
It configures the behavior when local log files on the provisioning server or a specific server reach the
Description
maximum file size.
0-Append Delete, the server will delete the old log and the phone will continue uploading log.
Permitted
Values
1-Append Stop, the phone will stop uploading log.
Default
0
Parameter static.auto_provision.local_log.backup.append.max_file_size
It configures the maximum size (in KB) of the local log files can be stored on the provisioning server or
Description
a specific server.
Permitted
Integer from 200 to 65535
Values
Default
1024
Parameter static.auto_provision.local_log.backup.bootlog.upload_wait_time <y0000000000xx>.cfg
It configures the waiting time (in seconds) before the phone uploads the boot log file to the pro-
Description
visioning server or a specific server after startup.
Permitted
Integer from 1 to 86400
Values
Default
120

Exporting the Log Files to a Local PC

Procedure
1. From the web user interface, go to Settings > Configuration.
2. In the Enable Local Log field, select Enabled or ON.
3. Select 6 from the Local Log Level drop-down menu.
The default local log level is "3".
4. Enter the limit size of the log files in the Max Log File Size field.
5. Click Confirm to accept the change.
6. Reproduce the issue.
7. Click Export to open the file download window, and then save the file to your local system.
A diagnostic file named <MAC>-syslog.zip is successfully exported to your local system.

Uploading Log to the USB Flash Drive

The phone log can be uploaded to the connected USB flash drive.
It is not applicable to
T48G/T46G/T42G/T41P/T40P/T40G/T33P/T33G/T31P/T31G/T31/T30P/T30/T29G/T23P/T23G/T21(P) E2/T19(P) E2
phones.
Procedure
1. From the web user interface, go to Settings > Configuration.
2. In the Enable Local Log field, select Enabled or ON.
3. In the USB Auto Exporting Syslog field, select Enabled or ON.
4. Select the desired value from the Local Log Level drop-down menu.
The default local log level is "3".