Administrator's Guide for SIP-T2 /T3 /T4 /T5 /CP920 IP Phones
Example: Keeping User's Personalized Settings
This section shows you how to keep the personalized settings.
Parameters Settings:
static.auto_provision.custom.protect =1
After provisioning, if the users make changes via the phone user interface or web user interface, the MAC-local.cfg
file with non-static personal settings generates locally.
Scenario: Keeping user's personalized settings when upgrading the firmware
If you set " static.auto_provision.custom.sync =1 ", then the phones attempt to upload the MAC-local.cfg file to the pro-
visioning server each time the file updates. When performing auto provisioning, they download their own MAC-