Omron OMNUC FND Series User Manual page 71

Position drivers
Table of Contents

Advertisement

Design and Installation
External Control Signal Connectors (CN4: LIMIT) Pin Arrangement
2
CWL
CW limit
Deceleration
stop
4
STOP
(see note)
6
8
j Connectors Used
Sumitomo 3M
Receptacle at Position Driver
Soldered plug at cable side
Case at cable side
Note The Servomotor cannot be driven if the deceleration stop signal if OFF for the external control
input (CN4-4) or the CompoBus/S input (OUT7).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
1
CCWL
CCW limit
Origin
3
ORG
proximity
5
+24-VDC
power sup-
7 +24 V
ply input for
control
9
11
13
10214-6202JL
10114-3000VE
10314-52A0-008
Chapter 2
Brake
8
BO
output
10
12
Output
14 OGND
ground
2-47