Appendices
No.
Name
Min. unit
UP-
25
Monitor
---
output
26
Motor
---
rotation
direction
28
Brake ON
0.1%
speed
29
Motor test
1 r/min
speed
0.1 Ω
30
External
regeneration
resistance
value
31
External
0.01 kW
regeneration
resistance
capacity
7-14
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Setting
Factory
range
setting
000 to
010
Specifies monitor output func-
011
tion.
0
0, 1
0
Specifies motor rotation direc-
tion.
0: Forward rotation
1: Reverse direction
0.0 to
1.0
Specifies r/min to turn OFF
100.0
break output in on-hold brake
mode.
Specifies rate based on rated
motor r/min as 100%.
* The brake may be damaged
if the on-hold brake mode is
selected for motors rotating
at high speed.
1 to
50
Specifies r/min for motors for
8,000
testing.
* When testing a motor, make
sure that the set value is
less than the rated motor r/
min.
0.0 to
0.0
Specifies the regeneration
100.0
absorption value (Ω).
* Only valid for FND-X50H- .
* When using an OMRON-
made external Regeneration
Resistor, set to 30.0 (Ω).
0.00 to
0.00
Specifies the regeneration
327.67
absorption capacity (kW).
Only valid for FND-X50H- .
Explanation
Positive voltage
0: Not reversed
1: Reversed
Speed/Current selection
0: Current
1: Speed
Chapter 7
Re-power
Set
required?
value
No
No
No
No
Yes
Yes

Advertisement