j PTP Parameters (PP-01 to PP-26)
No.
Name
PP-
01
Minimum set-
---
ting unit
02
Pulse rate 1
1 revo-
(Rotation)
lution
03
Pulse rate 2
1
(Movement)
04
Minimum res-
---
olution (left-
most digits)
05
Minimum res-
---
olution (right-
most digits)
06
Origin com-
1 pulse
pensation
(leftmost dig-
its)
07
Origin com-
pensation
(rightmost
digits)
08
Compensa-
(PP-01)
tion (leftmost
(See
digits)
note 1.)
09
Compensa-
tion (rightmost
digits)
(PP-01)
10
Forward soft-
(See
ware limit
note 1.)
(leftmost dig-
its)
11
Forward soft-
ware limit
(rightmost
digits)
(PP-01)
12
Reverse soft-
ware limit
(See
(leftmost dig-
note 1.)
its)
13
Reverse soft-
ware limit
(rightmost
digits)
14
Reference
1/s
speed (left-
most digits)
15
Reference
speed (right-
most digits)
7-16
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Min.
Setting
Factory
unit
range
setting
0.0001
0.0001
to 1
1 to
1
32,767
1 to
10
32,767
---
0.0
---
0042
–9,999
0
to
9,999
0 to
0
9,999
0 to
0
9,999
)
0 to
0
9,999
–9,999
9,999
to
9,999
0 to
9,999
9,999
–9,999
–9,999
to
9,999
0 to
9,999
9,999
0 to
0
9,999
0 to
500
9,999
Explanation
Specifies basic unit for move-
ment and speed value setting
and display.
Specifies PP-02 to n and
PP-03 to x (Note: "n" is the
number of motor revolutions
number of motor revolutions
and "x" is machine axis move-
ment.)
Displays the movement of the
mechanical axis per 1 motor
sensor pulse. (Setting not pos-
(
g
sible.)
)
Specifies number of motor sen-
sor pulses for movement be-
tween origin search completion
position and machine axis ori-
gin.
i
* The value can be obtained by
origin teaching.
Specifies backlash compensa-
tion if UP-01 is set to 11 or 13
in PTP control mode.
Specifies slip compensation if
S
UP-01 is set to 12 or 14 in
feeder control mode.
Specifies software limit position
in forward direction.
* The software limit overflow in
the ositive direction is not
the positive direction is not
detected if the value is set to
9999,9999.
Specifies software limit position
in reverse direction.
* The software limit overflow in
the reverse direction is not
the reverse direction is not
detected if the value is set to
–9999,9999.
Specifies machine axis refer-
ence speed per second.
Chapter 7
Re-power
Set
required?
value
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No

Advertisement