Omron OMNUC FND Series User Manual page 230

Position drivers
Table of Contents

Advertisement

Specifications
j Terminal Blocks (FND-X50H- )
Signal
Function
R0
Control power
S0
supply input
R
Main circuit power
S
supply input
T
P
Main circuit DC
JP1
output
JP2
Regeneration Re-
sistor connection
terminal
N
Main circuit DC
output
MC
Not used
COM
BO
BI1
BI2
A
Servomotor's A-
phase and U-
phase output
B
Servomotor's B-
phase and V-
phase output
C
Servomotor's C-
phase and W-
phase output
Frame ground
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
These are the power supply input terminals for the control circuit.
Single-phase 200/240 VAC (170 to 264 VAC) 50/60 Hz
These are the power supply input terminals for the main circuit.
Three-phase 200/240 VAC (170 to 264 VAC) 50/60 Hz
These are the connection terminals for the Regeneration Resistor
(R88A-RR20030/-RR40030). Connect them when the regeneration energy is
high.
When connecting a Regeneration Resistor, remove the short bar from be-
tween JP1 and JP2.
This is the main circuit DC output terminal.
(Do not connect anything to these terminals. Do not remove the short bar
from between BI1 and BI2.)
Red
These are the terminals for outputs to the Servomotor. Be careful to
wire them correctly. OMNUC Servomotors can be connected to
these terminals with R88A-CAUB
tors). OMRON does not provide a dedicated cable to connect these
) O
O
White
terminals to OMNUC M-series Servomotors, so the user must pro-
vide an appropriate cable if an M-series Servomotor is used.
Blue
or
black
Green This is the connection terminal. Use at a ground of 100 Ω or less.
This ground is used in common for Servomotor output and power
supply input.
Condition
Cable (for U-series Servomo-
(
Chapter 5
5-7