Omron OMNUC FND Series User Manual page 144

Position drivers
Table of Contents

Advertisement

Operation
This parameter specifies the direction for beginning an origin search operation.
Set value
0
Begins origin search in the positive direction (incrementing the present value).
1
Begins origin search in the negative direction (decrementing the present value).
PRM No.
Parameter name
PP-20
Acceleration time 0
PRM No.
Parameter name
PP-21
Acceleration time 1
These parameters specify the time from a stop until the reference speed is reached.
The actual acceleration time can be obtained from the following formula:
[(Target speed – present speed) / reference speed] x acceleration time
If S-curve acceleration time (UP-14) is set, the acceleration time will be lengthened.
Acceleration time 0 is used as the acceleration time for origin search, JOG operation, and positioning
by direct input.
When positioning with PTP data, acceleration time 0 or 1 can be selected using the PTP data's accel-
eration/deceleration selection (Pd
PRM No.
Parameter name
PP-22
Deceleration time 0
PRM No.
Parameter name
PP-23
Deceleration time 1
These parameters specify the time from the reference speed until the positioning is stopped.
The actual deceleration time can be obtained from the following formula:
[(Present speed – target speed) / reference speed] x deceleration time
Deceleration time 0 is used as the deceleration time for origin search, JOG operation, and positioning
by direct input.
When positioning with PTP data, deceleration time 0 or 1 can be selected using the PTP data's accel-
eration/deceleration selection (Pd
Acceleration/Deceleration Operation
Speed
Reference speed
(PP-14, PP-15)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
0 to 9,999
0 to 9,999
A).
0 to 9,999
0 to 9,999
A).
Acceleration time
Description
Setting range
Unit
ms
Setting range
Unit
ms
Setting range
Unit
ms
Setting range
Unit
ms
Actual motor response (example)
Deceleration time
Chapter 3
Factory setting
0
Factory setting
100
Factory setting
0
Factory setting
100
Time
3-31

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents