2.4 Cables installation

For a detailed description of the power source and wire feeder cabling, see Installing interconnection cable. For a full
overview of the cabling, see Cabling diagram.
"Installing interconnection cable" below
"Cabling diagram" on page 45

2.4.1 Installing interconnection cable

Install the interconnection cable first to the wire feeder and then to the power source.
Proceed as follows:
Connect the interconnection cable to the wire feeder:
1.
Lift the cable cabinet latch to reveal the connectors.
2.
Connect the welding current cable to the wire feeder. Push the cable as far as it goes and turn the connector clock-
wise to tighten the cable to its place.
Tighten the welding current cable as much as you can by hand. If the welding current cable connection is loose, it
may overheat.