DPulse
DPulse is a pulse welding process with two separate power levels. The welding power varies between these two levels,
and the parameters of each level are controlled independently. In the Welding view, toggle between level 1 and level 2
by pressing the left Control Pad button. The inactive power level is shown with a gray line on the wire feed speed dia-
gram.
Figure: DPulse Welding view
To adjust the welding power / wire feed speed while welding, in the Control Pad's Welding view, turn the left knob.
To fine tune voltage while welding, in the Control Pad's Welding view, turn the right knob.
When using DPulse, you can adjust the following parameters through Settings > Parameters:
Wire Feed Speed: adjusts the wire feed speed for level 1.
>> min: adjusts the minimum set value for wire feed speed
>> max: adjusts the maximum set value for wire feed speed
Fine tuning: adjusts the voltage (arc length).
Dynamics: Adjusts the short circuit behavior. On the minus side, the arc is softer (less spatter). On the plus side, the
arc is harder (the arc is more stable).
Pulse current %: -10...+15. Adjusts the pulse peak current. Use for controlling the droplet detachment.
StartPower: -30...+30. Adjusts the power level for arc ignition.
StartLevel: -30...+30. Fine tunes the arc length for arc ignition.
StopPower: -30...+30. Adjusts the power level for arc stop.
You can adjust the following parameters through Settings > DPulse: