2.
When you finish using the welding machine, log out of the system.
>> Power off the machine or scroll to Welder, press the green button, and select Log out.
Log out of the system to avoid the next welding data getting registered under your name.
In the WeldEye cloud service settings, you can filter the items that Control Pad shows to be identified. For example, you
can have the WPS and the filler batch number shown, but not the filler material or shielding gas. This does not prevent
you from scanning also other identifiers with the barcode reader.
Welding data collection: alarms in WeldEye services
Before welding, Control Pad shows alarms for insufficient welder qualifications, wrong filler material, and wrong shield-
ing gas. After welding, it shows an alarm if there are nonconforming welding parameters or heat input values.
Each welder's qualifications are stored in their personal qualification certificates in WeldEye. If a welder's certificate lacks
the necessary qualifications required by the WPS, the system raises an alert. If the welder restrains from welding, the sys-
tem drops the alert. However, if the welder starts to weld despite the alert, the system records the alert in the WeldEye
cloud service.
WeldEye also compares the filler material information and shielding gas information that the welder enters with Control
Pad to the filler and shielding gas defined in the WPS. If these do not match, the system raises an alert.
© Kemppi
120
X8 MIG Welder
Operating manual - EN
1902370 / 2324