© Polycom, Inc.
Field or Button
Name
Status Time
Status Change Time
Alarm Level
Average Latency
Successful
Attempts
Jitter
Last Latency
Max Latency
Std Dev Latency
Average Success Rate
Clear Alarm button
Reset Stats button
Chapter 5 - Setting Up and Working with Resources
Description
The time when the equipment was last checked by a
ReadiManager LX100
service.
The time at which the status changed from functioning to
non-functioning, or vice versa.
The level of the last alarm: Critical, Major, Minor, or None.
An alarm of "critical" indicates that
LX100
cannot communicate with the device. If alerts are
enabled and a critical alarm is received, a pager email is sent
to the facilitator and contact associated with the resource to
which this equipment is assigned.
An alarm of "major" indicates that
LX100
can establish an IP connection to the device, but it is
unable to determine the call status.
An alarm of "minor" is currently not used.
An alarm of "none" indicates there are no problems
communicating with the equipment.
Not currently used.
Number of times that alert management successfully
communicated with the equipment. The frequency with which
the equipment is checked depends on how many endpoints
are being checked.
Number of times that alert management attempted to
communicate with the equipment.
Measurement of the Jitter between the
ReadiManager LX100
Server and the equipment.
This measurement is automatically accumulated during the
polling of the device. It is updated after each polling cycle.
This is not related to the diagnostic jitter test available in the
Network Management screen, which is measured from the PC
that requests the diagnostic test.
Last measurement that was read.
Highest latency measurement that has been read.
Standard Deviation Latency Jitter measurement.
Average success rate of alarm management communicating
with the equipment.
Use this button to only reset the Alarm Level to None. Then
Update
click
to save the change.
Use this button to reset both the management statistics and
clear the alarm to a no-alarm condition. Then click
save the change.
Polycom
Polycom ReadiManager
Polycom ReadiManager
Polycom
Update
to
67
Need help?
Do you have a question about the ReadiManagerLX100 and is the answer not in the manual?
Questions and answers