2. Remove the Moving Arm:
a. Outer pivot shaft set screw: Do not remove, loosen or tighten the set screw,
this will damage the Nylock patch. The outer set screw does not need to be
removed or loosened to remove the moving arm.
b. Inner pivot shaft set screw: Remove the 3/16" hex key pivot shaft inner set
screw and gently pull the Moving Arm outward to remove. Discard the Nylock
set screw.
CAUTION: Do not reuse the inner or outer Nylock patch set screws for install-
ation. Either removing or loosening the Nylock set screw will compromise the
integrity of the Nylock patch. Discard and order new set screws for installation
(see
Exploded View
Installation Instructions
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Diagrams, bubble # 252).
6 Replacement Procedures
Moving Arms Replacement