5. Remove the one #2 Phillips screw fastener and
connect the Generator input cable (J1) and Eddy/Brake load cable (J7) from the
LPCA board. Retain part(s) and/or fastener(s) for installation.
6. Use a 1/2" socket to loosen the two Generator/Brake assembly and the two Drive
Components assembly carriage bolt nuts (left side). Do not remove the carriage bolt
nuts.
1
Lower Printed Circuit Assembly board; also refered to as the Lower PCA or simply as the
lower board. On treadmills, it is the console to base function interface and the motor con-
troller unit (MCU). On self-powered units, it is the lower PCA console to base function inter-
face.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
6 Replacement Procedures
Drive Components assembly Replacement
1
LPCA
/Battery module cover. Dis-
Page 120