Page 1
Manual WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR I/O Module for Terminating the Fieldbus Node; with Potential Group; Extreme Version 1.0.1...
Page 2
We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally protected by trademark or patent. WAGO is a registered trademark of WAGO Verwaltungsgesellschaft mbH. Manual Version 1.0.1...
WAGO I/O System 750 XTR Table of Contents 750-600/040-001 End Module with Potential Group XTR Table of Contents Notes about this Documentation ............. 5 Validity of this Documentation..............5 Copyright ....................5 Symbols ....................6 Number Notation ..................8 Font Conventions ................... 8 Important Notes ..................
Page 4
Table of Contents WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR 6.1.2 Marking for the United States of America (NEC) and Canada (CEC) ....................40 Installation Regulations................. 43 6.2.1 Special Notes including Explosion Protection ........43 6.2.2...
(End Module with Potential Group XTR). The I/O module 750-600/040-001 shall only be installed and operated according to the instructions in this manual, in the system description for the WAGO I/O System 750 XTR and in the manual for the used fieldbus coupler/controller.
Notes about this Documentation WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Symbols Personal Injury! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury. Personal Injury Caused by Electric Current! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury.
Page 7
WAGO I/O System 750 XTR Notes about this Documentation 750-600/040-001 End Module with Potential Group XTR Additional Information: Refers to additional information which is not an integral part of this documentation (e.g., the Internet). Manual Version 1.0.1...
Notes about this Documentation WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Number Notation Table 1: Number Notation Number Code Example Note Decimal Normal notation Hexadecimal 0x64 C notation Binary '100' In quotation marks, nibble separated '0110.0100'...
2.1.1 Subject to Changes WAGO GmbH & Co. KG reserves the right to provide for any alterations or modifications. WAGO GmbH & Co. KG owns all rights arising from the granting of patents or from the legal protection of utility patents. Third-party products are always mentioned without any reference to patent rights.
These modules contain no parts that can be serviced or repaired by the user. The following actions will result in the exclusion of liability on the part of WAGO GmbH & Co. KG: •...
WAGO I/O System 750 XTR Important Notes 750-600/040-001 End Module with Potential Group XTR Environmentally friendly disposal benefits health and protects the environment from harmful substances in electrical and electronic equipment. • Observe national and local regulations for the disposal of electrical and electronic equipment.
Important Notes WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Safety Advice (Precautions) For installing and operating purposes of the relevant device to your system the following safety precautions shall be observed: Do not work on devices while energized! All power sources to the device shall be switched off prior to performing any installation, repair or maintenance work.
Page 13
WAGO I/O System 750 XTR Important Notes 750-600/040-001 End Module with Potential Group XTR Inadequate wire cross sections can cause temperature increases! To avoid increasing thermal risks, only use conductor cross-sections sufficient for the required maximum load current. The conductor cross-sections specified in the technical data refer exclusively to the mechanical connection capacity of the clamping points.
Page 14
Important Notes WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Protect the components against materials having seeping and insulating properties! The components are not resistant to materials having seeping and insulating properties such as: aerosols, silicones and triglycerides (found in some hand creams).
WAGO I/O System 750 XTR Device Description 750-600/040-001 End Module with Potential Group XTR Device Description An end module must be snapped onto the assembly at the end of a fieldbus node. The end module completes the internal data bus, while providing correct data transmission.
Device Description WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Connectors 3.2.1 Data Contacts/Local Bus Communication between the coupler/controller and the I/O modules as well as the system supply of the I/O modules is carried out via the local bus. It is comprised of 6 data contacts, which are available as self-cleaning gold spring contacts.
Device Description WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Schematic Diagram Figure 4: Schematic Diagram Manual Version 1.0.1...
WAGO I/O System 750 XTR Device Description 750-600/040-001 End Module with Potential Group XTR Technical Data 3.6.1 Device Data Table 5: Technical Data – Device Width 12 mm Depth (from upper edge of DIN-rail) 60.6 mm Height 100 mm Weight...
Device Description WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR 3.6.5 Climatic Environmental Conditions Table 10: Technical Data ‒ Climatic Environmental Conditions Surrounding air temperature, operation −40 °C … +70 °C Surrounding air temperature, storage −40 °C … +85 °C...
WAGO I/O System 750 XTR Device Description 750-600/040-001 End Module with Potential Group XTR Approvals For current approvals, please go to: www.wago.com/<Item number>. The following approvals have been granted to 750-600/040-001 I/O modules: Conformity Marking UL E175199 for use in Ordinary...
Page 22
Device Description WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR The following ship approvals are pending for 750-600/040-001 I/O modules: ABS (American Bureau of Shipping) LR (Lloyd’s Register) Env. 1, 2, 3, 4 For more information about the ship approvals: Note the “Supplementary Power Supply Regulations”...
WAGO I/O System 750 XTR Device Description 750-600/040-001 End Module with Potential Group XTR Standards and Guidelines 750-600/040-001 I/O modules meet the following standards and guidelines: Table 11: Standards and Rated Conditions for Explosion Protection Applications ATEX acc. Directive 2014/34/EU...
Device Description WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Table 12: Climatic and Mechanical Environmental Conditions and Shipbuilding Standard Test Value Transport EN 60870-2-2 Ct2(2k4) (except precipitation/water/moisture) Mechanical Environmental Conditions EN 61850-3 Achieved EN 60870-2-2...
WAGO I/O System 750 XTR Device Description 750-600/040-001 End Module with Potential Group XTR The I/O module 750-600/040-001 meets the following EMC standards as these standards relate to the I/O module: Table 13: EMC – Product- and Generic Standards EN IEC 61000-6-1...
WAGO I/O System 750 XTR Device Description 750-600/040-001 End Module with Potential Group XTR Table 15: EMc – Testing Standards: Emission of Interference Standard Test Value Enclosure Emission of Interference • EN 55016-2-3 30 dB(µV/m), QP, 30 MHz … 230 MHz 37 dB(µV/m), QP, 230 MHz …...
Page 28
Device Description WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Table 15: EMc – Testing Standards: Emission of Interference Standard Test Value • EN 55032 Class B 40 dB(μA) … 30 dB(μA) QP, 0.15 MHz ... 0.5 MHz 30 dB(μA) …...
MTBF values (acc. to MIL-HDBK-217-F2) are available and can be provided on request for specific projects WAGO is a company certified in accordance with the IRIS quality standard. Table 17: Further EMC Requirements for Railroad Applications Requirement Fulfills Class EBA Regulation No. EMC 06...
750-600/040-001 End Module with Potential Group XTR Mounting Mounting Sequence Fieldbus couplers, controllers and I/O modules of the WAGO I/O System 750 are snapped directly on a carrier rail in accordance with the European standard EN 60175 (DIN 35). The reliable positioning and connection is made using a tongue and groove system.
WAGO I/O System 750 XTR Mounting 750-600/040-001 End Module with Potential Group XTR Inserting and Removing Devices Do not touch hot surfaces! The surface of the housing can become hot during operation. If the device was operated at high ambient temperatures, allow it to cool off before touching it.
Mounting WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Once the end module has snapped into place, the electrical connection for the data contacts to the preceding I/O module is established The end module completes the internal data bus, while providing correct data transmission.
Do not connect more than one conductor at one single connection! If more than one conductor must be routed to one connection, these must be connected in an up-circuit wiring assembly, for example using WAGO feed- through terminals. For opening the CAGE CLAMP ®...
Connect Devices WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Connection Examples The following connection examples are possible in connection with the I/O module 750-677/0x0-000: Figure 8: Connection to I/O Module 750-677 (all Channels with Inverted Configured Output).
Use in Hazardous Environments 750-600/040-001 End Module with Potential Group XTR Use in Hazardous Environments The WAGO I/O System 750 (electrical equipment) is designed for use in Zone 2 hazardous areas and shall be used in accordance with the marking and installation regulations.
Use in Hazardous Environments WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Marking Configuration Examples 6.1.1 Marking for Europe According to ATEX and IECEx Figure 10: Marking Example per ATEX and IECEx Figure 11: Text Detail – Marking Example per ATEX and IECEx Manual Version 1.0.1...
WAGO I/O System 750 XTR Use in Hazardous Environments 750-600/040-001 End Module with Potential Group XTR Table 18: Description of the Marking Example per ATEX and IECEx Marking Text Description TUEV 07 ATEX 554086 X Approving authority or certificate numbers IECEx TUN 09.0001 X...
Use in Hazardous Environments WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Figure 12: Marking Example of an Approved I/O Module Ex i per ATEX and IECEx Figure 13: Text Detail – Marking Example of an Approved I/O Module Ex i...
WAGO I/O System 750 XTR Use in Hazardous Environments 750-600/040-001 End Module with Potential Group XTR Table 19: Description of the Marking Example of an Approved I/O Module Ex i per ATEX and IECEx Marking Text Description TUEV 12 ATEX 106032 X...
Use in Hazardous Environments WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR 6.1.2 Marking for the United States of America (NEC) and Canada (CEC) Figure 14: Marking Example According to NEC Figure 15: Text Detail – Marking Example According to NEC 500...
WAGO I/O System 750 XTR Use in Hazardous Environments 750-600/040-001 End Module with Potential Group XTR Figure 16: Text Detail – Marking Example for Approved I/O Module Ex i According to NEC 505 Table 21: Description of Marking Example for Approved I/O Module Ex i According to NEC 505...
Use in Hazardous Environments WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Figure 18: Text Detail – Marking Example for Approved I/O Module Ex i According to CEC 18 attachment J Table 23: Description of Marking Example for Approved I/O Module Ex i According to CEC 18...
WAGO I/O System 750 XTR Use in Hazardous Environments 750-600/040-001 End Module with Potential Group XTR Installation Regulations For the installation and operation of electrical equipment in hazardous areas, the valid national and international rules and regulations which are applicable at the installation location must be carefully followed.
Page 44
Use in Hazardous Environments WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR Explosive atmosphere occurring simultaneously with assembly, installation or repair work must be ruled out. Among other things, these include the following activities • Insertion and removal of components •...
WAGO I/O System 750 XTR Use in Hazardous Environments 750-600/040-001 End Module with Potential Group XTR 6.2.2 Special Notes Regarding UL Hazardous Location For UL Hazardous Location acc. to UL File E198726, the following additional requirements apply: • Use in Class I, Division 2, Group A, B, C, D or non-hazardous areas only •...
List of Figures WAGO I/O System 750 XTR 750-600/040-001 End Module with Potential Group XTR List of Figures Figure 1: View ....................15 Figure 2: Data Contacts ..................16 Figure 3: CAGE CLAMP ® Connector ..............17 Figure 4: Schematic Diagram ................18 Figure 5: Snap the End Module into Place ............31 Figure 6: Removing the End Module ..............32...
WAGO I/O System 750 XTR List of Tables 750-600/040-001 End Module with Potential Group XTR List of Tables Table 1: Number Notation ................... 8 Table 2: Font Conventions .................. 8 Table 3: Legend for Figure “View” ..............15 Table 4: Legend for Figure “CAGE CLAMP ®...
Page 48
WAGO GmbH & Co. KG Postfach 2880 • D - 32385 Minden Hansastraße 27 • D - 32423 Minden Phone: +49 571 887 – 0 Fax: +49 571 887 – 844169 E-Mail: info@wago.com Internet: www.wago.com...