Table 194: Ethernet Link - WAGO -I/O-SYSTEM 750 XTR Manual

Fc ethernet g3 xtr fieldbus coupler ethernet; 3rd generation; extreme
Hide thumbs Also See for WAGO-I/O-SYSTEM 750 XTR:
Table of Contents

Advertisement

WAGO-I/O-SYSTEM 750 XTR
750-352/040-000 FC ETHERNET G3 XTR
Instance 1
Table 194: Ethernet link (F6
Attribute ID
1
2
3
6
7
8
) – Instance 1
hex
Acces
Name
s
Get
Interface Speed
Get
Interface Flags
Get
Physical Address ARRAY of
Set
Interface Control
Control Bits
Forced Interface
Speed
Get
Interface Type
Get
Interface Status
Fieldbus Communication 205
Data type Description
UDINT
Transfer rate
DWORD
Interface configuration
and status information
Bit 0: Link status
Bit 1: Half/full duplex
Bit 2...4: Detection
status
Bit 5: Manual settings
require reset
Bit 6: Local hardware
error
Bit 7...31: Reserved
MAC layer address
6 UINTs
STRUCT
Configuration of the
of:
physical interface
WORD
Interface configuration
bits
Bit 0: Automatic
detection
Bit 1: Default duplex
mode
Bit 2...15: Reserved
UINT
Preset interface speed 10 (0x000A) or
USINT
Interface type
Value 0: Unknown
Value 1: Internal
interface; e.g., in the
case of an integrated
switch
Value 2: Twisted pair
(e.g. 100Base-TX).
Value 3: fiber glass
(e.g. 100Base-FX).
Value 4...256:
Reserved
USINT
Interface status
Value 0: Unknown
Value 1: Interface
active and ready to
send/receive.
Value 2: Interface
deactivated.
Value 3: Interface is
testing
Wert 4...256:
Reserved
Default value
10 (0x0A) or
100 (0x64)
Value is dependent
upon Ethernet
connection.
MAC ID of the device
-
0x0001
100 (0x0064)
2 (0x02) – Twisted
Pair
-