750-352/040-000 FC ETHERNET G3 XTR
Output Process Image
Bit 7
Controls
DO 8
Channel 8
12.2.3.3

16-Channel Digital Output Modules

Table 264: 16-Channel Digital Output Modules

Output Process Image
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Con-
Con-
trols
trols
DO 16
DO 15
Chan-
Chan-
nel
nel
16
15
Pos : 100.4 /D okumentati on allgemei n/Gli ederungsel emente/---Seitenwec hs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1
Pos : 100.5 /Serie 750 ( WAGO-I/O-SYST EM)/Pr ozessabbild M appi ng/ETH ERNET - EtherNet/IP - M ODBU S/TC P/PA ETH ERN ET - AIs-Ei nlei tung MOD BUS/TCP (INTEL, mit word- alignment) @ 7\mod_1272352811572_21.doc x @ 55815 @ 3 @ 1
12.2.4

Analog Input Modules

The hardware of an analog input module has 16 bits of measured analog data
per channel and 8 bits of control/status.
However, the coupler/controller with MODBUS/TCP does not have access to the
8 control/status bits.
Therefore, the coupler/controller with MODBUS/TCP can only access the 16 bits
of analog data per channel, which are grouped as words and mapped in Intel
format in the Input Process Image.
Pos : 100.6 /Serie 750 ( WAGO-I/O-SYST EM)/Pr ozessabbild M appi ng/Sofern i n dem Knoten auc h Digital eingangs module gestec kt, z u AIs @ 8\mod_1279112061364_21.doc x @ 59903 @ @ 1
When digital input modules are also present in the node, the analog input data is
always mapped into the Input Process Image in front of the digital data.
Pos : 100.7 /Serie 750 ( WAGO-I/O-SYST EM)/Pr ozessabbild M appi ng/Informati on - Informati onen z um Steuer-/Status byteaufbau @ 4\mod_1238055708743_21.doc x @ 29070 @ @ 1
Information on the structure of control and status bytes
For detailed information on the structure of a particular I/O module's
control/status bytes, please refer to that module's manual. Manuals for each
module can be found on the Internet at www.wago.com.
Pos : 100.8 /Serie 750 ( WAGO-I/O-SYST EM)/Pr ozessabbild M appi ng/ETH ERNET - EtherNet/IP - M ODBU S/TC P/PA ETH ERN ET - AIs XTR @ 16\mod_1374048837793_21.doc x @ 126378 @ 444 @ 1
12.2.4.1

2-Channel Analog Input Modules

Table 265: 2-Channel Analog Input Modules

Input Process Image
Offset
0
1
Bit 6
Bit 5
Controls
Controls
DO 7
DO 6
Channel 7
Channel 6
Channel 5
Con-
Con-
Con-
Con-
Con-
trols
trols
trols
trols
DO 14
DO 13
DO 12
DO 11
DO 10
Chan-
Chan-
Chan-
Chan-
Chan-
nel
nel
nel
nel
14
13
12
11
Byte designation
High byte
D1
D3
Bit 4
Bit 3
Controls
Controls
Controls
DO 5
DO 4
Channel 4
Channel 3
Con-
Con-
Con-
Con-
trols
trols
trols
trols
trols
DO 9
DO 8
DO 7
DO 6
Chan-
Chan-
Chan-
Chan-
nel
nel
nel
nel
10
9
8
7
Low byte
D0
D2
I/O Modules 229
Bit 2
Bit 1
Controls
Controls
DO 3
DO 2
Channel 2
Channel 1
Con-
Con-
Con-
Con-
trols
trols
trols
trols
DO 5
DO 4
DO 3
DO 2
Chan-
Chan-
Chan-
Chan-
nel
nel
nel
nel
nel
6
5
4
3
Remark
Measured value channel 1
Measured value channel 2
Manual
Version 1.3.0
Bit 0
DO 1
Con-
trols
DO 1
Chan-
nel
2
1