8.5

Setting Date and Time

Pos : null /Serie 750 (WAGO-I/O-SYST EM)/In Betrieb nehmen/F eldbus knoten i n Betri eb nehmen/U hrzei t und D atum eins tell en, Hinweis, Lis tenpunkte, Z wischenüberschrift: ..." Eth Settings" ( Koppler @ 33\mod_1547826826035_21.doc x @ 523823 @ @ 1
The fieldbus coupler's system time enables a date and time indication for files in
the flash file system.
System time will be reset when the controller is de-energized!
The fieldbus coupler 750-352/040-000 does not have a real-time clock. For this
reason, the current system time will be reset when the controller is de-energized!
After switching on the operating voltage, the system time starts at 01/01/2000
00:00:00 a.m.
At start-up, synchronize the system time with the computer's current time.
There are two options to synchronize the system time:
Synchronize the system time using "WAGO Ethernet Settings"
Synchronize the system time using the Web Based Management System
Synchronize the system time using "WAGO Ethernet Settings"
Pos : null /Serie 750 (WAGO-I/O-SYST EM)/Web-Bas ed-M anagement-Sys tem WBM /Seite Cloc k/Hi nweis : U hrzeit nic ht während ei ner WAGO I/O-CH ECK Kommuni kati on ei nstellen! @ 33\mod_1543847260289_21.doc x @ 512059 @ @ 1
Do not set time during a WAGO I/O-CHECK communication!
Note that setting the clock during a WAGO I/O-CHECK communication may
cause communication errors. Therefore set the time only if WAGO I/O-CHECK is
not yet started.
Pos : null /Serie 750 (WAGO-I/O-SYST EM)/In Betrieb nehmen/F eldbus knoten i n Betri eb nehmen/Betriebss pg aussc halten, Kommuni kations kabel ansc hließ en, Bertri ebss pg an (Controll er) Sc hritt 1- 3 @ 8\mod_1275649569537_21.doc x @ 57380 @ @ 1
1.
Switch off the supply voltage of the fieldbus controller.
2.
Connect the communication cable 750-920 or 750-923 respectively the
Bluetooth
controller and to your computer.
3.
Switch on the supply voltage of the fieldbus controller.
Pos : null /Serie 750 (WAGO-I/O-SYST EM)/In Betrieb nehmen/F eldbus knoten i n Betri eb nehmen/H oc hlauf und LEDs ( Koppl er) @ 4\mod_1243590574487_21.doc x @ 34500 @ @ 1
The fieldbus coupler is initialized. The coupler determines the I/O module
configuration and creates a process image.
During start-up, the I/O LED (red) flashes.
If the I/O LED lights up green after a brief period, the fieldbus coupler is
operational.
Pos : null /Serie 750 (WAGO-I/O-SYST EM)/In Betrieb nehmen/F eldbus knoten i n Betri eb nehmen/H oc hlauf und LEDs - F ehler allgemei n, Hinweis: Signalisierung/Blinkc ode- Aus w. @ 4\mod_1243594306433_21.doc x @ 34538 @ @ 1
If an error occurs during start-up indicated by the I/O LED flashing red, evaluate
the error code and argument and resolve the error.
®