Replacing A Cpu Or Heat Sink - Fujitsu PRIMERGY RX2530 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2530 M4:
Table of Contents

Advertisement

Processor (CPU)
I
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There is
no technical problem.
Proceed as follows:
Ê Restart your server.
Ê As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
If a password is assigned, enter the password and press [Enter].
Ê Select the Save & Exit menu.
Ê Select Save Changes and Exit or Save Changes and Reset.
Ê Verify that the Global Error indicator stops flashing.
"Resuming BitLocker functionality" on page 98
Ê
11.3

Replacing a CPU or heat sink

Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver
V
CAUTION!
CPUs are modules which are extremely sensitive to electrostatic
discharges and therefore must always be handled with care. After a CPU
has been removed from its protective sleeve or from its socket, place it
with its smooth side down on a non-conducting, antistatic surface. Never
push a CPU over a surface.
298
Upgrade and Maintenance Manual
Hardware: 15 minutes
Software: 5 minutes
RX2530 M4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents