7.4.6
Replacing a 2.5-inch HDD/SSD module
Customer Replaceable Unit
(CRU)
Tools: Phillips PH1 / (+) No. 1 screw driver (if moving installation frame)
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
●
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see section
hot-plug HDD/SSD module" on page
An HDD/SSD module can be replaced while the system is in
●
operation.
RAID configuration with a RAID controller:
– Modular Host Bus Adapter with "Integrated RAID" (IR). RAID
levels 0 and 1 are supported for internal HDD configurations.
– Modular RAID 0/1 controller with "MegaRAID functionality"
(integrated MegaRAID). RAID levels 0, 1,10,5 and 50 are
supported for internal HDD configurations.
– Modular RAID 5/6 controller with "MegaRAID functionality"
(MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported
for internal HDD configurations. As an option, a flash backup unit
(FBU) can save the memory content even if the power fails.
Cache memory size of up to 8 GB is available.
RAID configuration without a RAID controller:
Please follow the instruction of each software e.g. VSAN, Storage
Spaces, and Storage Spaces Direct, provided separately to use the
software RAID function of OS or Hypervisor.
All HDD/SSD modules (drives) must be uniquely identified so that
●
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
RX2530 M4
Hard disk drive (HDD) / solid state drive (SSD)
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Indicators on the
426.
161