7.4.6

Replacing a 2.5-inch HDD/SSD module

Customer Replaceable Unit
(CRU)
Tools: Phillips PH1 / (+) No. 1 screw driver (if moving installation frame)
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not
currently being accessed. Observe the indicators for the
corresponding HDD/SSD modules, see section
hot-plug HDD/SSD module" on page
An HDD/SSD module can be replaced while the system is in
operation.
RAID configuration with a RAID controller:
– Modular Host Bus Adapter with "Integrated RAID" (IR). RAID
levels 0 and 1 are supported for internal HDD configurations.
– Modular RAID 0/1 controller with "MegaRAID functionality"
(integrated MegaRAID). RAID levels 0, 1,10,5 and 50 are
supported for internal HDD configurations.
– Modular RAID 5/6 controller with "MegaRAID functionality"
(MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported
for internal HDD configurations. As an option, a flash backup unit
(FBU) can save the memory content even if the power fails.
Cache memory size of up to 8 GB is available.
RAID configuration without a RAID controller:
Please follow the instruction of each software e.g. VSAN, Storage
Spaces, and Storage Spaces Direct, provided separately to use the
software RAID function of OS or Hypervisor.
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
RX2530 M4
Hard disk drive (HDD) / solid state drive (SSD)
Upgrade and Maintenance Manual
Hardware: 5 minutes
"Indicators on the
426.