Verifying System Information Backup/Restore - Fujitsu PRIMERGY RX2530 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX2530 M4:
Table of Contents

Advertisement

Basic software procedures
Ê During POST, press [F12] and select the connected USB stick as boot
device. The system will detect the USB stick.
Ê Choose the Recovery_L option from the update tool menu to start the iRMC
update process.
V
CAUTION!
Do not interrupt the iRMC upgrade process after it has started. If the
process is interrupted, the iRMC BIOS may be permanently
corrupted.
I
If the iRMC does not work after flashing, disconnect the system from
the mains and reconnect it again.
Ê Shut down the server by pressing the power On/Off button.
Ê Disconnect the server from the mains to exit the iRMC recovery state.
5.2.2

Verifying system information backup/restore

To avoid the loss of non-default settings when replacing the system board, a
backup copy of important system configuration data is automatically stored from
the system board NVRAM to the Chassis ID EPROM. After replacing the
system board the backup data is restored from the Chassis ID board to the new
system board.
In order to verify whether the backup or restore process has been successful,
check the System Event Log (SEL) using the ServerView Operations Manager
(see also section
page
95).
After replacing the system board
Ê Check the SEL log files as described in section
System Event Log (SEL)" on page 95
the Chassis ID EPROM has been restored to the system board:
Chassis IDPROM: Motherboard Exchange detected
Chassis IDPROM: BMC FW restore successful
Chassis IDPROM: BIOS restore successful
84
"Viewing and clearing the System Event Log (SEL)" on
Upgrade and Maintenance Manual
"Viewing and clearing the
to verify whether the backup data on
RX2530 M4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents