Figure 282: Removing the TPM screw
Ê Locate the slotted lower end of the TPM screw (1).
Ê Carefully loosen the TPM screw using a thin slotted screw driver (e.g.
watchmaker's screw driver) or the dedicated TPM screw driver (Japan) (2).
V
CAUTION!
Ensure to turn the screw clockwise in order to remove it!
Slowly and carefully increase the pressure on the screw until it begins
to turn. The effort when loosing the screw should be as low as
possible.
Otherwise the thin metal bar may break, rendering it impossible to
loosen the screw.
Ê Remove the TPM screw (3).
Ê Remove the TPM on the upper side of the system board.
RX2530 M4
Upgrade and Maintenance Manual
System board and components