16.7.1.3 Installing the new system board
Ê Check the settings on the new system board, see section
on page
433.
Ê Insert the system board by holding it at a slight angle. Slide the connectors
into the I/O panel (see figure
Ê Lower the system board carefully into the chassis.
Ê Adjust the system board. If necessary adjust the position of the system
board with a gentle twisting motion (orange circles in figure
show the centering bolts).
Ê Fasten the system board with the 12 screws (see figure
Ê Fasten the four OCP bolts (see figure
Ê For Japan / APAC / North America only:
Replace the CMOS battery installed on the new system board with a new
CMOS battery (see section
because charging of CMOS battery might be reduced during stocked in
warehouse.
Ê System with air cooling:
Ê Remove the heat sink with the CPU from the defective system board, see
section
"Removing the heat sink" on page
Ê Remove the protective plastic cover from the CPU socket of the new
system board and fit it onto the socket of the defective system board
which will be sent back to spares.
I
Returned system boards without this cover probably have to be
scrapped.
Ê Install the heat sink with the CPU on the new system board, see section
"Installing the CPU and heat sink" on page
Ê System with liquid cooling:
Ê Remove the protective plastic cover from the CPU socket of the new
system board and fit it onto the socket of the defective system board
which will be sent back to spares.
I
Returned system boards without this cover probably have to be
scrapped.
RX2530 M4
302 on page
"Replacing the CMOS battery" on page
Upgrade and Maintenance Manual
System board and components
404).
300 on page
402).
299.
303.
"Onboard settings"
301 on page 403
301 on page
403).
367),
405