17.2.2.3 Indicators on the hot-plug HDD/SSD module
Figure 318: Indicators on the hot-plug HDD/SSD module
Pos. Label
1
2
426
Indicator
Status
off
Access
indicator
green on
off
orange
on
Error
indicator
flashing
orange
slowly
Upgrade and Maintenance Manual
Description
The HDD/SSD is inactive.
The HDD/SSD being accessed
No HDD/SSD error detected.
An HDD/SSD error has been
detected.
Possible causes:
– The drive is defective and
needs replacing.
– A RAID rebuild process has
failed.
– The HDD/SSD module has not
been inserted correctly.
HDD/SSD RAID rebuild is in
progress. Data is being restored
after replacing a drive that has
been combined into a RAID array.