17.4
Minimum startup configuration
Field Replaceable Units (FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
System board
1 CPU with CPU heat sink
1 memory module
Front panel module
1 PSU
Table 3: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 4: Minimum startup configuration - cables
"Shutting down the server" on page 49
Ê
"Disconnecting the power cord" on page 50
Ê
Ê Take the system down to its minimum startup configuration.
"Connecting the power cord" on page 63
Ê
Ê Connect a display to the server.
Ê Switch on the server, see section
434
Notes
no TPM or expansion cards installed
installed in CPU slot CPU 1
installed in DIMM slot 1A
installed in PSU bay PSU 1
Notes
"Switching on the server" on page
Upgrade and Maintenance Manual
66.