3HAC027151-001 Revision: T
Action
DANGER
Turn off all:
electric power supply to the
robot
hydraulic pressure supply
to the robot
air pressure supply to the
robot
Before entering the robot working
area.
Remove the cable harness, axes
1-3.
Let the removed part of the cable
harness hang loose and take care
not to damage it during the remov-
al process.
Remove the attachment screws
M16x50 (16 pcs) that secure the
lower arm to gearbox axis 2.
Remove the upper and lower arms
and put them down on the floor.
Remove motor axis 2.
Remove two attachment screws
(M12x60) parallel to each other.
Fit two guide pins in the holes,
parallel to each other.
CAUTION
The gearbox weighs 98 kg! All lift-
ing equipment used must be sized
accordingly!
© Copyright 2006-2018 ABB. All rights reserved.
4.7.2 Replacement gearbox axis 2
Note
Detailed in the section
Replacement of cable har-
ness, lower end (axes 1-2) on page
Shown in the figure
Location of gearbox axis 2 on
page
286.
Detailed in the section
Replacement of motor axis
2 on page
247.
Continues on next page
4 Repair
Continued
185.