3 Maintenance
3.4.6 Changing oil, axis-5 gearbox
Continued
2
3
4
5
6
Filling, oil, axis 5
The procedure below details how to change the oil in gearbox, axis 5.
When using the oil exchange equipment, follow the instructions enclosed with the
kit. Art. no. for the kit is specified in
1
2
3
Continues on next page
164
Action
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
WARNING
Handling gearbox oil involves several safety risks.
Before proceeding, please read the safety inform-
ation in the section
Safety risks during work with
gearbox lubricants (oil or grease) on page
Remove the oil plug, filling.
Drain the oil from the gearbox by opening the oil
plug, draining.
Refit the oil plug, draining.
Action
Run axis 4 to a position where the oil plug, filling,
is facing upwards.
WARNING
Handling gearbox oil involves several safety risks.
Before proceeding, please read the safety inform-
ation in the section
Safety risks during work with
gearbox lubricants (oil or grease) on page
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
© Copyright 2006-2018 ABB. All rights reserved.
Note
37.
Shown in the figure
gearbox on page
Vessel capacity is specified in
quired equipment on page
Tightening torque: 24 Nm.
Required equipment on page
Note
37.
Product manual - IRB 6620
3HAC027151-001 Revision: T
Location of