3 Maintenance
3.5.1 Cleaning the IRB 6620
Continued
Cleaning methods
The following table defines what cleaning methods are allowed depending on the
protection type.
Protection
type
Standard
Foundry Plus
i
Cleaning with water and steam
Instructions for rinsing with water
ABB robots with protection types Standard, Foundry Plus, Wash, or Foundry Prime
can be cleaned by rinsing with water (water cleaner).
The following list defines the prerequisites:
I
Instructions for steam or high pressure water cleaning
ABB robots with protection types Foundry Plus, Wash, or Foundry Prime can be
cleaned using a steam cleaner or high pressure water cleaner.
The following list defines the prerequisites:
1
See
Cleaning methods on page 174
2
See
Cleaning methods on page 174
Continues on next page
174
Never use solvents that are not approved by ABB to clean the robot.
Do not spray from a distance closer than 0.4 m.
Do not remove any covers or other protective devices before cleaning the
robot.
Cleaning method
Vacuum
Wipe with cloth
cleaner
Yes
Yes. With light
cleaning deter-
gent.
Yes
Yes. With light
cleaning deter-
gent or spirit.
Perform according to section
Maximum water pressure at the nozzle: 700 kN/m
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum flow: 20 liters/min
Typical tap water pressure and flow
Maximum water pressure at the nozzle: 2500 kN/m
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum water temperature: 80° C
for exceptions.
for exceptions.
© Copyright 2006-2018 ABB. All rights reserved.
Rinse with water
Yes. It is highly re-
commended that
the water contains
a rust-prevention
solution and that
the manipulator is
dried afterwards.
Yes. It is highly re-
commended that
the water contains
a rust-prevention
solution.
Cleaning with water and steam on page
I
High pressure water or
steam
No
i
Yes
.
It is highly recommended
that the water and steam
contains rust preventive,
without cleaning deter-
gents.
174.
1
2
I
(7 bar)
2
2
(25 bar)
Product manual - IRB 6620