4 Repair
4.3.1 Replacement of cable harness, lower end (axes 1-2)
Continued
5
6
7
8
Continues on next page
188
Action
Disconnect the earth cable.
Disconnect connectors R1.MP
and R1.SMB on the connection
plate, base.
Disconnect all connectors at
motors 1 R2.MP1, R2.FB1 and
2 R2.MP2, R2.FB2.
Remove the metal clamps on
the frame, securing the cable
harness.
© Copyright 2006-2018 ABB. All rights reserved.
Note
xx0600003028
A: Earth (placed beneath the top cover)
B: Top cover, connection box
Shown in the figure
Location of cable harness, axes
1-2 on page
185.
Shown in the figure
Location of cable harness, axes
1-2 on page
185.
Shown in the figure
Location of cable harness, axes
1-2 on page
185.