Sign In
Upload
Manuals
Brands
Agilent Technologies Manuals
Measuring Instruments
16754A
Agilent Technologies 16754A Manuals
Manuals and User Guides for Agilent Technologies 16754A. We have
2
Agilent Technologies 16754A manuals available for free PDF download: Service Manual
Agilent Technologies
16753A
Service Manual
Agilent Technologies 16754A Service Manual (136 pages)
Logic Analyzers
Brand:
Agilent Technologies
| Category:
Measuring Instruments
| Size: 3.65 MB
Table of Contents
Logic Analyzers
2
Table of Contents
6
1 General Information
10
Accessories
11
Mainframe and Operating System
11
Specifications
12
Characteristics
13
Environmental Characteristics
14
Recommended Test Equipment
15
2 Preparing for Use
16
Power Requirements
17
Operating Environment
17
Storage
17
To Inspect the Module
17
To Configure and Install the Module
18
To Test the Module
18
To Clean the Module
18
3 Testing Logic Analyzer Performance
20
Equipment Required
23
Assemble the Sma/Flying Lead Test Connectors
24
Set up the Test Equipment
29
Connect the Test Equipment
31
Verify and Adjust the 8133A Pulse Generator DC Offset
33
Deskew the Oscilloscope
34
Set the 8133A Pulse Width
36
Testing the Module Using a 16900-Series Mainframe
38
Do a Self-Test on the 16900-Series Logic Analysis System
39
Configure the 16900-Series Logic Analysis System
40
Adjust Sampling Positions Using Eye Finder
44
To Re-Align a Stray Channel
46
Test Pod 1 in 300 Mb/S Mode
47
Determine PASS/FAIL (1 of 2 Tests)
47
Close the Eye Finder and Analyzer Setup Windows
47
Configure the Markers
47
Determine PASS/FAIL (2 of 2 Tests)
49
Test the Complement of the Bits (300 Mb/S Mode)
50
Test Pod 2 in 300 Mb/S Mode
52
Test the Complement of the Bits (Pod 2, 300 Mb/S Mode)
53
Test Pods 3 and 4 in 300 Mb/S Mode
54
Test Pod 1 in 600 Mb/S Mode
54
Determine and Set Eye Finder Position (600 Mb/S Mode)
55
Test the Complement of the Bits (Pod 1, 600 Mb/S Mode)
56
Test Pod 2 in 600 Mb/S Mode
57
Test the Complement of the Bits (Pod 2, 600 Mb/S Mode)
59
Test Pods 3 and 4 in 600 Mb/S Mode
59
Conclude the State Mode Tests
60
Performance Test Record
61
Testing the Module Using a 16700-Series Mainframe
62
Do a Self-Test on the 16700-Series Logic Analysis System
63
Configure the 16700-Series Logic Analysis System
64
Adjust Sampling Positions Using Eye Finder
69
To Re-Align a Stray Channel
70
Test Pod 1 in 300 Mb/S Mode
72
Determine PASS/FAIL (1 of 2 Tests)
72
Open and Configure the Listing Window
72
Determine PASS/FAIL (2 of 2 Tests)
74
Test the Complement of the Bits (300 Mb/S Mode)
76
Test Pod 2 in 300 Mb/S Mode
78
Test the Complement of the Bits (Pod 2, 300 Mb/S Mode)
79
Test Pods 3 and 4 in 300 Mb/S Mode
80
Test Pod 1 in 600 Mb/S Mode
80
Determine and Set Eye Finder Position (600 Mb/S Mode)
81
Test the Complement of the Bits (Pod 1, 600 Mb/S Mode)
83
Test Pod 2 in 600 Mb/S Mode
84
Test the Complement of the Bits (Pod 2, 600 Mb/S Mode)
85
Test Pods 3 and 4 in 600 Mb/S Mode
86
Conclude the State Mode Tests
86
Performance Test Record
87
4 Calibrating
88
Calibration Strategy
89
5 Troubleshooting
90
To Use the Flowcharts
91
To Run the Self Tests (16900-Series Mainframe)
94
To Run the Self-Tests (16700-Series Mainframe)
94
Self-Test Descriptions
95
To Exit the Test System (16900-Series Mainframe)
99
To Exit the Test System (16700-Series Mainframe)
99
To Test the Cables (16900-Series Mainframe)
100
To Test the Cables (16700-Series Mainframe)
105
6 Replacing Assemblies
114
Tools Required
115
To Remove the Module
115
To Remove the Logic Analyzer Cable
116
To Install the Logic Analyzer Cable
118
To Replace the Circuit Board
120
To Return Assemblies
121
7 Replaceable Parts
122
Replaceable Parts Ordering
123
Replaceable Parts List
124
Exploded View
127
8 Theory of Operation
128
Block-Level Theory
129
Index
132
Safety Notices
134
Advertisement
Agilent Technologies 16754A Service Manual (136 pages)
Logic Analyzers
Brand:
Agilent Technologies
| Category:
Measuring Instruments
| Size: 6.47 MB
Table of Contents
Table of Contents
6
General Information
10
Accessories
11
Mainframe and Operating System
11
Specifications
12
Characteristics
13
Environmental Characteristics
14
Recommended Test Equipment
15
Preparing for Use
16
Power Requirements
17
Operating Environment
17
Storage
17
To Inspect the Module
17
To Configure and Install the Module
18
To Test the Module
18
To Clean the Module
18
Testing Logic Analyzer Performance
20
Equipment Required
23
Assemble the Sma/Flying Lead Test Connectors
24
Set up the Test Equipment
29
Connect the Test Equipment
31
Verify and Adjust the 8133A Pulse Generator DC Offset
33
Deskew the Oscilloscope
34
Set the 8133A Pulse Width
36
Testing the Module Using a 16900-Series Mainframe
38
Do a Self-Test on the 16900-Series Logic Analysis System
39
Configure the 16900-Series Logic Analysis System
40
Adjust Sampling Positions Using Eye Finder
44
To Re-Align a Stray Channel
46
Test Pod 1 in 300 Mb/S Mode
47
Determine PASS/FAIL (1 of 2 Tests)
47
Close the Eye Finder and Analyzer Setup Windows
47
Configure the Markers
47
Determine PASS/FAIL (2 of 2 Tests)
49
Test the Complement of the Bits (300 Mb/S Mode)
50
Test Pod 2 in 300 Mb/S Mode
52
Test the Complement of the Bits (Pod 2, 300 Mb/S Mode)
53
Test Pods 3 and 4 in 300 Mb/S Mode
54
Test Pod 1 in 600 Mb/S Mode
54
Determine and Set Eye Finder Position (600 Mb/S Mode)
55
Test the Complement of the Bits (Pod 1, 600 Mb/S Mode)
56
Test Pod 2 in 600 Mb/S Mode
57
Test the Complement of the Bits (Pod 2, 600 Mb/S Mode)
59
Test Pods 3 and 4 in 600 Mb/S Mode
59
Conclude the State Mode Tests
60
Performance Test Record
61
Testing the Module Using a 16700-Series Mainframe
62
Do a Self-Test on the 16700-Series Logic Analysis System
63
Configure the 16700-Series Logic Analysis System
64
Adjust Sampling Positions Using Eye Finder
69
To Re-Align a Stray Channel
70
Test Pod 1 in 300 Mb/S Mode
72
Determine PASS/FAIL (1 of 2 Tests)
72
Open and Configure the Listing Window
72
Determine PASS/FAIL (2 of 2 Tests)
74
Test the Complement of the Bits (300 Mb/S Mode)
76
Test Pod 2 in 300 Mb/S Mode
78
Test the Complement of the Bits (Pod 2, 300 Mb/S Mode)
79
Test Pods 3 and 4 in 300 Mb/S Mode
80
Test Pod 1 in 600 Mb/S Mode
80
Determine and Set Eye Finder Position (600 Mb/S Mode)
81
Test the Complement of the Bits (Pod 1, 600 Mb/S Mode)
83
Test Pod 2 in 600 Mb/S Mode
84
Test the Complement of the Bits (Pod 2, 600 Mb/S Mode)
85
Test Pods 3 and 4 in 600 Mb/S Mode
86
Conclude the State Mode Tests
86
Performance Test Record
87
Calibrating
88
Calibration Strategy
89
Troubleshooting
90
To Use the Flowcharts
91
To Run the Self Tests (16900-Series Mainframe)
94
To Run the Self-Tests (16700-Series Mainframe)
94
Self-Test Descriptions
95
To Exit the Test System (16900-Series Mainframe)
99
To Exit the Test System (16700-Series Mainframe)
99
To Test the Cables (16900-Series Mainframe)
100
To Test the Cables (16700-Series Mainframe)
105
Replacing Assemblies
114
Tools Required
115
To Remove the Module
115
To Remove the Logic Analyzer Cable
116
To Install the Logic Analyzer Cable
118
To Replace the Circuit Board
120
To Return Assemblies
121
Replaceable Parts
122
Replaceable Parts Ordering
123
Replaceable Parts List
124
Exploded View
127
Theory of Operation
128
Block-Level Theory
129
Index
132
Advertisement
Related Products
Agilent Technologies 16753A
Agilent Technologies 16755A
Agilent Technologies 16756A
Agilent Technologies 16700 SERIES LOGIC ANALYSIS SYSTEM 16700
Agilent Technologies 16700 Series
Agilent Technologies 16712A
Agilent Technologies 16718A
Agilent Technologies 16716A
Agilent Technologies 1670E Series
Agilent Technologies 1670A Series
Agilent Technologies Categories
Measuring Instruments
Laboratory Equipment
Test Equipment
Water Pump
Power Supply
More Agilent Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL