7.2 Replacing the Control Board 2
Removal
(1) Remove the Arm #3 cover.
Control Board 2
(2) Disconnect the connector connected to the control board 2.
(3) Remove the control board 2.
NOTE
N6 Rev.2
Cross recessed binding head machine screws:
6-M4×8
Connector: GS02
Cross recessed binding head machine screws: 4-M3×6
Be careful not to drop the screws inside the Manipulator while removing them.