Battery - Epson N6 Series Manipulator Manual

6-axis robots
Table of Contents

Advertisement

6. Battery

■ Do not connect or disconnect the motor connectors while the power to the robot
system is turned ON. Connecting or disconnecting the motor connectors with
the power ON is extremely hazardous and may result in serious bodily injury as
the Manipulator may move abnormally, and also may result in electric shock
and/or malfunction of the robot system.
■ To shut off power to the robot system, disconnect the power plug from the power
source. Be sure to connect the AC power cable to a power receptacle.
DO NOT connect it directly to a factory power source.
WARNING
■ Before performing any replacement procedure, turn OFF the Controller and
related equipment, and then disconnect the power plug from the power source.
Performing any replacement procedure with the power ON is extremely
hazardous and may result in electric shock and/or malfunction of the robot
system.
■ Take meticulous care when handling the lithium metal battery. Improper
handling of the battery as mentioned below is extremely hazardous and may
result in heat generation, leakage, explosion, or inflammation.
It also may cause serious safety problems.
<Improper Handling>
Attempting to charge
Disassembling
Connecting batteries improperly
WARNING
Exposing to fire
Forcing discharge
■ When disposing the battery, consult with the professional disposal services or
comply with the local regulation. Make sure that the battery terminal is
insulated, even for a used buttery. If the terminal contacts with the other metals,
it may short and result in heat generation, leakage, explosion, or inflammation.
In case of the low battery (lithium metal battery) power, the error to warn the voltage
reduction occurs at the Controller startup (the software startup). All position data will be
lost and you will need to calibrate all joints.
The life span of the lithium metal battery varies depending on the energizing hours and
installation environment of the Controller. It is about 3 years as a rough guide (when the
Controller is connected to power for 8 hours a day). When the Controller is not
connected to power, the battery consumption will significantly increase compared to when
the Controller is energized. If warnings of voltage reduction occur, replace the lithium
metal battery even if it has not reached the above product life.
For the EPSON RC+ 7.0 Ver. 7.2.x or later (firmware Ver.7.2.x.x or later), the
NOTE
recommended replacement time for the battery can be checked in the [Maintenance] dialog
box of the EPSON RC+ 7.0.
For details, refer to the following manual.
N6 Rev.2
Robot Controller RC700 / RC700-A Maintenance 6. Alarm
Maintenance 6. Battery
Deforming by pressure
Short-circuit (Polarity; Positive/Negative)
Heating (85 °C or more)
Soldering the terminal of the lithium battery
directly
323