Joint #1 (N6-A850*R): Cable Direction: Standard (Backward) - Epson N6 Series Manipulator Manual

6-axis robots
Table of Contents

Advertisement

Maintenance 5. Actuator Units

5.1.3 Joint #1 (N6-A850*R): Cable direction: Standard (backward)

Removal
(1) Remove the covers.
Joint #1
Actuator Unit
N6-A850*R
(2) Remove the cable unit inside the Joint #1.
Cable direction:
Standard
(backward)
(3) Disconnect the M/C cable.
(4) Lay down the Manipulator.
NOTE
(5) Remove the base bottom plate.
(6)
NOTE
(7)
NOTE
274
Base cover, Joint #1 cover, and Joint #1 inside cover
For details, refer to Maintenance 3. Covers.
For details, refer to the Removal steps (7), (49) through (58), and (60) in
Maintenance 4.3 Cable Unit (N6-A850*R): Cable direction Standard (backward).
For details, refer to Maintenance 4.6. M/C Cable
Be sure to have at least 2 people to lay down the Manipulator.
Hexagon socket head cap bolts: 4-M4×8
Remove the base.
Hexagon socket head cap bolts:
8-M6×40 (with plain washer)
When you remove it, be careful not to catch
the cables on the Joint #1 actuator unit.
Remove the Joint #1 actuator unit and the
O-ring.
Hexagon socket head cap bolts:
16-M5×35 (with plain washer)
Be sure to have at least 2 people to perform
the operation since the parts being heavy.
Do not apply excessive shock to the parts.
8-M6×40 (with plain washer)
16-M5×35 (with plain washer)
Joint #1 actuator unit
N6 Rev.2

Advertisement

Table of Contents
loading

Table of Contents