Conversion Rules (Mr-J3-_A_ => Mr-J4-_A_) - Mitsubishi Electric MELSERVO-J3 Series Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 5: Common Reference Material
2.2.5 Conversion rules (MR-J3-_A_ => MR-J4-_A_)
The following table shows the servo parameter conversion rules from MR-J3-_A_ to MR-J4- _B_.
Servo parameters not specified in the following table will be set to the initial values.
No.
Name
PA01 Control mode
PA02 regenerative option
PA03 Absolute position detection system
PA04 Function selection A-1
Number of command input pulses
PA05
per revolution
Electronic gear numerator
PA06
(Command pulse multiplying factor
numerator)
Electronic gear denominator
PA07
(Command pulse multiplying factor
denominator)
PA08 Auto tuning mode
PA09 Auto tuning response
PA10 In-position range
PA11 Forward rotation torque limit
PA12 Reverse rotation torque limit
PA13 Command pulse input form
PA14 Rotation direction selection
POINT
Because the servo parameters of MR-J3-_A _ and those of MR-J4-_A_ are not
completely interchangeable, the conversion rules may not be applied. Check the
operations and review the settings as necessary.
The value of the parameter writing after parameter conversion is the initial value.
• MR-J4-_A_: [Pr. PA19] = "00AAh"
Various offset parameters cannot be converted. Change the settings as
necessary.
• MR-J4-_A_: [Pr. PC37] to [Pr. PC40]
The following parameters of MR-J4-_A_ are compatible with the servo amplifier's
software version A3 or later. The software version can be checked in the
system configuration.
• MR-J4-_A_: [Pr. PA03 Absolute position detection system "_ _ _2h" (Absolute
position detection system by communication)]
• MR-J4-_A_: [Pr. PC21 RS-422 communication function selection]
When the geared servo motor is replaced, the reduction ratio may differ before
and after the replacement. Check the specifications of the servo motor and
review the electronic gear settings as necessary.
• MR-J4-_A_: [Pr. PA05] to [Pr. PA07]
MR-J3-_A_
Type
Hex
Hex
Hex
Hex
Dec
Dec
Dec
Hex
Dec
Dec
Dec
Dec
Hex
Dec
MR-J4-_A_
Target
No.
Type
_ _ _ X
PA01
Hex
_ _ XX
PA02
Hex
_ _ _ X
PA03
Hex
_ _ _ X
PD24
Hex
PA05
Dec
-
PA21
Hex
-
PA06
Dec
-
PA07
Dec
_ _ _ X
PA08
Hex
-
PA09
Dec
-
PA10
Dec
-
PA11
Dec
-
PA12
Dec
_ _ XX
PA13
Hex
-
PA14
Dec
Hex: hexadecimal parameter; Dec: decimal parameter
5 - 41
Conversion rule
Target
_ _ _ X
The setting value will be maintained.
_ _ XX
The setting value will be maintained.
01_ _ will be changed to _ _ 01.
_ _ _ X
02_ _ will be changed to _ _ 02.
Otherwise, _ _ 00 will be set.
01_ _ will be changed to _ _ 05.
(MBR)
_ _ XX
The setting value other than above
will not be maintained.
0 will be changed to 10000.
-
Otherwise, the setting value will be
maintained.
0 will be changed to 2_ _ _.
X_ _ _
Otherwise, 1_ _ _ will be set.
-
The setting value will be maintained.
-
The setting value will be maintained.
_ _ _ X
The setting value will be maintained.
The value 4 is added to the setting
-
value.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
_ _ XX
The setting value will be maintained.
-
The setting value will be maintained.