Mitsubishi Electric MELSERVO-J3 Series Manual page 104

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
(5) Comparison of signals
MR-J3-_B_ < 7 kW or less >
Connector pin assignment
CN3
1
2
12
LG
DI1
DI2
3
4
14
DOCOM
MO1
MO2
5
6
16
DICOM
LA
LAR
7
8
18
LB
LZ
LZR
9
10
20
INP
EM1
DICOM
Note 1. Signals unique to MR-J4-_B_ are in parentheses.
2. The factory setting for MR-J4-_B_ is EM2.
Connector pin No.
CN3-1
CN3-2
CN3-3
CN3-4
11
CN3-5
CN3-6
LG
CN3-7
13
CN3-8
MBR
CN3-9
CN3-10
15
CN3-11
ALM
CN3-12
17
CN3-13
CN3-14
LBR
CN3-15
19
CN3-16
CN3-17
DI3
CN3-18
CN3-19
CN3-20 (Note 2)
Plate
Abbreviation
(Note 1)
Connector pin No.
LG
CN3-1
DI1
CN3-2
DOCOM
CN3-3
MO1
CN3-4
DICOM
CN3-5
LA
CN3-6
LB
CN3-7
LZ
CN3-8
INP
CN3-9
DICOM
CN3-10
LG
CN3-11
DI2
CN3-12
MBR
CN3-13
MO2
CN3-14
ALM
CN3-15
LAR
CN3-16
LBR
CN3-17
LZR
CN3-18
DI3
CN3-19
EM1
CN3-20
(EM2)
SD
Plate
3 - 11
MR-J4-_B_
Connector pin assignment
CN3
1
11
2
12
LG
LG
DI1
DI2
3
13
4
14
MBR
DOCOM
MO1
MO2
5
15
6
16
ALM
DICOM
LA
LAR
7
17
8
18
LB
LBR
LZ
LZR
9
19
10
20
INP
DI3
EM2
DICOM

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents