4.5.4 External I/O signal status (DIO diagnosis)

(1) Reading input device status
The following shows how to read the status of the input devices.
(a) Transmission
Transmit command [1] [2] and data No. [0] [0].
(b) Return
The slave station returns the status of the input devices.
Bit
Symbol
0
SON
1
LSP
2
LSN
3
TL
4
TL1
5
PC
6
RES
7
CR
(2) Reading external input pin status
The following shows how to read the on/off status of the external input pins.
(a) Transmission
Transmit command [1] [2] and data No. [4] [0].
(b) Return
The on/off status of the input pins are returned.
Bit
CN1 connector pin
0
43
1
44
2
42
3
15
4
19
5
41
6
16
7
17
Command
Data No.
[1] [2]
[0] [0]
b31
Command of each bit is transmitted to the master station as hexadecimal data.
Bit
Symbol
8
SP1
9
SP2
10
SP3
11
ST1/RS2
12
ST2/RS1
13
CM1
14
CM2
15
LOP
Command
Data No.
[1] [2]
[4] [0]
b31
Command of each bit is transmitted to the master station as hexadecimal data.
Bit
CN1 connector pin
8
18
9
45
10
11
12
13
14
15
5 - 82
Bit
Symbol
16
17
18
19
20
STAB2
21
22
23
Bit
CN1 connector pin
16
17
18
19
20
21
22
23
b1b0
1: On
0: Off
Bit
Symbol
24
25
26
27
CDP
28
CLD
29
MECR
30
31
b1b0
1: On
0: Off
Bit
CN1 connector pin
24
25
26
27
28
29
30
31