Part 7: Review on Replacement of Optional Peripheral Equipment

1.2 Regenerative Options (400 V class)

1.2.1 Combination and regenerative power for the MR-J3 series

List of regenerative options
Servo amplifier model
MR-J3-60A4/B4
MR-J3-100A4/B4
MR-J3-200A4/B4
MR-J3-350A4/B4
MR-J3-500A4/B4
MR-J3-700A4/B4
MR-J3-11KA4/B4
MR-J3-11KA4/B4-LR
MR-J3-15KA4/B4
MR-J3-15KA4/B4-LR
MR-J3-22KA4/B4
Servo amplifier model
MR-J3-60A4/B4
MR-J3-100A4/B4
MR-J3-200A4/B4
MR-J3-350A4/B4
MR-J3-500A4/B4
MR-J3-700A4/B4
MR-J3-11KA4/B4
MR-J3-11KA4/B4-LR
MR-J3-15KA4/B4
MR-J3-15KA4/B4-LR
MR-J3-22KA4/B4
Note 1. Always install a cooling fan.
2. The values in the parentheses are applied to when a cooling fan is installed.
Permissible regenerative power of regenerative option [W] MR-RB
Built-in
regenerative
(Note 1)
1H-4
resistor
3M-4
[82Ω]
[W]
[120Ω]
15
100
15
100
100
100
130
170
Built-in
(Note 2)
regenerative
Standard accessories
resistor
[External]
[W]
15
15
100
100
130
170
GRZG400-5Ω × 4
500(800)
GRZG400-2.5Ω × 4
500 (800)
GRZG400-2.5Ω × 5
850 (1300)
GRZG400-2Ω × 5
850 (1300)
(Note 1)
(Note 1)
(Note 1)
3G-4
34-4
3U-4
[47Ω]
[26Ω]
[22Ω]
300
300
300
300
300
300
Permissible regenerative power of regenerative
(Note 2)
5K-4
[10Ω]
500
(800)
7 - 6
(Note 1)
(Note 1)
(Note 1)
5G-4
54-4
5U-4
[47Ω]
[26Ω]
[22Ω]
500
500
500
500
option [W] MR-RB
(Note 2)
(Note 2)
(Note 2)
6B-4
60-4
6K-4
[20Ω]
[12.5Ω]
[10Ω]
500
(800)
850
(1300)
850
(1300)
850
(1300)