Configuration Diagram - Mitsubishi Electric MELSERVO-J3 Series Manual

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 1: Summary of MR-J3/MR-J3W Replacement

3.1.2 Configuration diagram

The following displays the review items when replacing MR-J3 series with MR-J4 series using MR-J3-100A
or less as an example case.
R S T
Power supply
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
Line noise filter
(FR-BSF01)
L
L
3
Power factor
improving DC
reactor
(FR-BEL)
Note.
"MR Configurator2" can also be used for MR-J3 series/MR-J3W series.
L
1
2
P
1
P
2
P
C
Regenerative
option
L
11
L
21
CN6
Servo amplifier
CN5
CN3
CN1
CN2
CN4
Battery
MR-J3BAT
U V W
1 - 4
Options and
Peripheral equipment
Analog monitor
Personal
Setup software
computer
(SETUP221E)
(Note)
Junction terminal block
Servo motor