Configure an electromagnetic brake circuit so that it is activated also by an external emergency stop switch.
Contacts must be opened with the ALM (malfunction)
off or the MBR (electromagnetic brake interlock) off.
When any alarm has occurred, eliminate its cause, ensure safety, and deactivate the alarm before
restarting operation.
If the molded-case circuit breaker or fuse is activated, be sure to remove the cause and secure safety
before switching the power on. If necessary, replace the servo amplifier and recheck the wiring.
Otherwise, it may cause smoke, fire, or an electric shock.
Provide an adequate protection to prevent unexpected restart after an instantaneous power failure.
To prevent an electric shock, injury, or fire from occurring after an earthquake or other natural disasters,
ensure safety by checking conditions, such as the installation, mounting, wiring, and equipment before
switching the power on.
(6) Maintenance, inspection and parts replacement
Make sure that the emergency stop circuit operates properly such that an operation can be stopped
immediately and a power is shut off by the emergency stop switch.
It is recommended that the servo amplifier be replaced every 10 years when it is used in general
environment.
When using a servo amplifier whose power has not been turned on for a long time, contact your local
sales office.
(7) General precautions
To illustrate details, the equipment in the diagrams of this Replacement Manual may have been drawn
without covers and safety guards. When the equipment is operated, the covers and safety guards must be
installed as specified. Operation must be performed in accordance with Instruction Manual.
CAUTION
Servo motor
RA
Electromagnetic
B
brake
U
CAUTION
A - 6
Contacts must be opened with
the EMG stop switch.
24VDC