Mitsubishi Electric MELSERVO-J3 Series Manual page 66

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
MR-J3-_A_
No.
Name and function
PB23
Low-pass filter selection
Select the low-pass filter.
0 0 x 0:
Low-pass filter selection
0: Automatic setting
1: Manual setting ([Pr. PB18] setting)
When automatic setting has been selected, select
the filter that has the band width close to the one
calculated with
VG2 10
[rad/s]
1 + GD2
PB24
Slight vibration suppression control selection
Select the slight vibration suppression control.
When [Pr. PA08] (auto tuning mode) is set to "_ _ _
3", the slight vibration suppression control is made
valid.
0 0 0 x:
Slight vibration suppression control selection
0: Invalid
1: Valid
PB25
Function selection B-1
Select the control systems for position command
acceleration/deceleration time constant ([Pr.
PB03]).
0 0 x 0:
Control of position command acceleration/
deceleration time constant
0: Primary delay
1: When linear acceleration/deceleration is
selected, do not execute control switching after
instantaneous power failure. The servo motor will
make a sudden stop during the control switching
or automatic restart.
Initial
No.
value
0000h
PB23
Same setting as MR-J3
Low-pass filter selection
Shaft resonance suppression filter selection
_ _ _ x:
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When "Machine resonance suppression filter 4
selection" is set to "Enabled (_ _ _ 1)" in [Pr. PB49],
the shaft resonance suppression filter is not
available.
_ _ x _:
Low-pass filter selection
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
0000h
PB24
Same as MR-J3
Slight vibration suppression control
Slight vibration suppression control selection
_ _ _ x:
Select the slight vibration suppression control.
0: Disabled
1: Enabled
To enable the slight vibration suppression control,
set "Gain adjustment mode selection" to "Manual
mode (_ _ _ 3)" in [Pr. PA08]. Slight vibration
suppression control cannot be used in the speed
control mode.
_ _ x _:
For manufacturer setting
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
0000h
PB25
Function selection B-1
_ _ _ x:
Model adaptive control selection
0: Enabled (model adaptive control)
2: Disabled (PID control)
This parameter is supported with software version
B4 or later.
_ _ x _:
Position acceleration/deceleration filter type
selection
Select the position acceleration/deceleration filter
type.
0: Primary delay
1: Linear acceleration/deceleration
When you select "Linear acceleration/deceleration",
do not switch the control mode. Doing so will cause
the servo motor to make a sudden stop at the time
of control mode switching.
_ x _ _:
For manufacturer setting
x _ _ _:
For manufacturer setting
2 - 37
MR-J4-_A_
Name and function
Control
Initial
mode
value
0h
P
S
T
0h
P
S
T
0h
0h
0h
P
0h
0h
0h
P
0h
P
0h
0h
0h

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents