No.
Name and function
PB20
Vibration suppression control resonance frequency
setting
This parameter cannot be used in the speed control
mode.
Set the resonance frequency for vibration suppression
control to suppress low-frequency machine vibration,
such as enclosure vibration.
When [Pr. PB02] is set to "_ _ _ 2" , this parameter can
be set manually.
PB21
This parameter is not used. Do not change the value.
PB22
This parameter is not used. Do not change the value.
PB23
Low-pass filter selection
Select the low-pass filter.
0 0 x 0:
Low-pass filter selection
0: Automatic setting
1: Manual setting ([Pr. PB18] setting)
When automatic setting has been selected, select the
filter that has the band width close to the one calculated
VG2・
10
with
[rad/s]
1
+
GD2
MR-J3W-_B
Initial
No.
value
100.0
PB20
Vibration suppression control 1 - Resonance frequency
Set the resonance frequency for vibration suppression
control 1 to suppress low-frequency machine vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in [Pr.
PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written
to the parameter is used.
0.00
PB21
Vibration suppression control 1 - Vibration frequency
damping
Set a damping of the vibration frequency for vibration
suppression control 1 to suppress low-frequency
machine vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in [Pr.
PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written
to the parameter is used.
0.00
PB22
Vibration suppression control 1 - Resonance frequency
damping
Set a damping of the resonance frequency for vibration
suppression control 1 to suppress low-frequency
machine vibration.
When "Vibration suppression control 1 tuning mode
selection" is set to "Automatic setting (_ _ _ 1)" in [Pr.
PB02], this parameter will be set automatically. When
"Manual setting (_ _ _ 2)" is selected, the setting written
to the parameter is used.
0000h
PB23
Low-pass filter selection
Select the shaft resonance suppression filter and low-
pass filter.
_ _ _ x:
Shaft resonance suppression filter selection
0: Automatic setting
1: Manual setting
2: Disabled
When you select "Enabled (_ _ _ 1)" of "Machine
resonance suppression filter 4 selection" in [Pr. PB49],
the shaft resonance suppression filter is not available.
_ _ x _ :
Low-pass filter selection
0: Automatic setting
1: Manual setting
2: Disabled
_ x _ _ :
For manufacturer setting
x _ _ _ :
For manufacturer setting
4 - 29
MR-J4W2-_B
Name and function
Initial
value
100.0
0.00
0.00
0h
0h
0h
0h