Part 7: Review on Replacement of Optional Peripheral Equipment

7.5 MR-J4 series Power factor improving AC reactors (200 V/100 V class)

The following shows the advantages of using power factor improving AC reactor.
It improves the power factor by increasing the form factor of the servo amplifier's input current.
It decreases the power supply capacity.
The input power factor is improved to be about 80%.
When using power factor improving reactors for two servo amplifiers or more, be sure to connect a power
factor improving reactor to each servo amplifier. If using only one power factor improving reactor, enough
improvement effect of phase factor cannot be obtained unless all servo amplifiers are operated.
When using the MR-J4W2 servo amplifier together with the rotary servo motor, select a power factor
improving AC reactor tentatively, assuming one type of the servo motors are used for 2 axes. After the
tentative selections are made for all types of the servo motors, use the largest among all power factor
improving AC reactors.
W1
W or less (Note 2)
Note 1.
Use this hole for grounding.
2.
W ± 2 is applicable for FR-HAL-0.4K to FR-HAL-1.5K.
W1
W ± 2
Note Use this hole for grounding.
Terminal layout
R X
S Y T
Z
4-d mounting hole
(Varnish is removed from front right mountin
hole (face and back side).) (Note 1)
D or less
D2
D1
Fig. 7.9
Terminal layout
R X
S Y T
Z
4-d mounting hole
(Varnish is removed from front right mounting
hole (face and back side).) (Note)
D or less
D2
D1
Fig. 7.10
3-phase
200 V AC to
240 V AC
(Note)
1-phase
200 V AC to
240 V AC
1-phase
100 V AC to
120 V AC
Note For 1-phase 200 V AC to 240 V AC, connect the power
supply to L1 and L3. Leave L2 open.
R
S
X
Y
W1
W or less
Note Use this for grounding.
7 - 55
Servo amplifier
3-phase 200 V class
FR-HAL
MCCB
MC
R
X
L1
S
Y
L2
T
Z
L3
Servo amplifier
1-phase 200 V class
FR-HAL
MCCB
MC
R
X
L1
S
Y
L2
T
Z
L3
Servo amplifier
1-phase 100 V class
FR-HAL
MCCB
MC
R
X
L1
S
Y
Unassigned
T
Z
L2
4-d mounting hole (Note)
D or less
T
Z
D1 ± 2
Fig. 7.11
D2