Mitsubishi Electric MELSERVO-J3 Series Manual page 471

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 7: Review on Replacement of Optional Peripheral Equipment
Rating plate
Terminal box - screw size G
E
A or less
2-F
L notch
Note 1. Since the terminal cover is supplied, attach it after connecting a wire.
2.When using power factor improving DC reactor, disconnect P
3.When 11k to 22kW, "P
Power factor
Servo amplifier
improving DC
reactor
MR-J3-10A/20A
FR-BEL-0.4K
MR-J3-40A
FR-BEL-0.75K
MR-J3-60A/70A
FR-BEL-1.5K
MR-J3-100A
FR-BEL-2.2K
MR-J3-200A
FR-BEL-3.7K
MR-J3-350A
FR-BEL-7.5K
MR-J3-500A
FR-BEL-11K
MR-J3-700A
FR-BEL-15K
MR-J3-11KA
MR-J3-15KA
FR-BEL-22K
MR-J3-22KA
FR-BEL-30K
MR-J3-60A4
FR-BEL-H1.5K
MR-J3-100A4
FR-BEL-H2.2K
MR-J3-200A4
FR-BEL-H3.7K
MR-J3-350A4
FR-BEL-H7.5K
MR-J3-500A4
FR-BEL-H11K
MR-J3-700A4
FR-BEL-H15K
MR-J3-11KA4
MR-J3-15KA4
FR-BEL-H22K
MR-J3-22KA4
FR-BEL-H30K
Note Selection condition of wire size is as follows.
Wire type: 600 V Polyvinyl chloride insulated wire (IV wire)
Construction condition: One wire is constructed in the air
Servo amplifier
FR-BEL-(H)
P
1
(Note 2)
P
2
5m or less
H
B or less
Mounting leg
F
Fig.7.1
" becomes "P", respectively.
2
Outline
drawing
A
B
110
50
120
53
130
65
Fug. 7.1
130
65
150
75
150
75
170
93
170
93
Fug. 7.2
185
119
185
119
130
63
130
63
Fug. 7.1
150
75
150
75
170
93
170
93
Fug. 7.2
185
119
185
119
Rating plate
(Note 1)Terminal cover
Screw size G
E
A or less
2-F
and P
.
1
2
Dimensions [mm]
C
D
E
F
L
94
1.6
95
6
12
102
1.6
105
6
12
110
1.6
115
6
12
110
1.6
115
6
12
102
2.0
135
6
12
126
2.0
135
6
12
132
2.3
155
6
14
170
2.3
155
6
14
182
2.6
165
7
15
201
2.6
165
7
15
89
1.6
115
6
12
101
1.6
115
6
12
102
2
135
6
12
124
2
135
6
12
132
2.3
155
6
14
160
2.3
155
6
14
171
2.6
165
7
15
189
2.6
165
7
15
7 - 48
FR-BEL-(H)
(Note 2)
H
B or less
L notch
Mounting leg
F
Fig.7.2
Mounting
screw size
[kg (lb)]
G
H
M3.5
25
M5
M4
25
M5
M4
30
M5
M4
30
M5
M4
40
M5
M5
40
M5
M5
50
M5
M8
56
M5
M8
70
M6
M8
70
M6
M3.5
32
M5
M3.5
32
M5
M4
40
M5
M4
40
M5
M5
50
M5
M6
56
M5
M6
70
M6
M6
70
M6
Servo amplifier
P
1
(Note 3)
P
2
5m or less
Mass
Wire
2
[mm
] (Note)
0.5
0.7
1.1
2 (AWG14)
1.2
1.7
2.3
3.5 (AWG12)
3.1
5.5 (AWG10)
8 (AWG8)
3.8
22 (AWG4)
5.4
30 (AWG2)
6.7
60 (AWG2/0)
0.9
1.1
2 (AWG14)
1.7
2.3
3.1
5.5 (AWG10)
3.7
8 (AWG8)
5.0
22 (AWG4)
6.7

Hide quick links: