(1) Comparison of MR-J3 series and MR-J4 series (General-purpose interface/SSCNETIII interface)
Item
1
Capacity range
2
Regenerative resistor
3
Dynamic brake
4
Control circuit power
5
Main circuit power
6
24 V DC power
7
Auto tuning
8
Control mode
Maximum input pulses
9
(General-Purpose Interface)
The number of DIO points
10
(excluding EM1)
11
Encoder pulse output
12
DIO interface
13
Analog input/output
Note 1. For the coasting distance, refer to "1.2.3 Dynamic brake: coasting distance" in "Part 5 Common Reference Material".
MR-J3 series
(100 V class) 0.1 kW to 0.4 kW
(200 V class) 0.1 kW to 22 kW
(400 V class) 0.6 kW to 22 kW
Built-in (0.2 kW to 7 kW)
External (11 kW to 22 kW)
Built-in (0.1 kW to 7 kW)
External (11 kW to 22 kW)
(100 V class)
1-phase 100V AC to 120V AC
(200 V class)
1-phase 200V AC to 230V AC
(400 V class)
1-phase 380V AC to 480V AC
(100 V class)
1-phase 100V AC to 120V AC
(200 V class)
1-phase 230V AC
3-phase 200V AC to 230V AC (0.1 kW to 750 W)
3-phase 200V AC to 230V AC (0.1 kW to 22 kW)
(400 V class)
3-phase 380V AC to 480V AC
External supply required
Real-time auto tuning: 32 steps
Advanced gain search
General-Purpose Interface
Position control mode (pulse command)
Speed control mode (analog command)
Torque control mode (analog command)
SSCNET III Interface (50 Mbps)
Position control mode
Speed control mode
Differential pulse: 1 Mpulse/s
Command pulse: Sink
General-Purpose Interface
DI: 9 points, DO: 6 points
SSCNET III Interface
DI: 3 points, DO: 3 points
ABZ-phase (differential line driver)
General-Purpose Interface
Z-phase (open collector)
input/output: sink/source
General-Purpose Interface
(Input) 2ch
10-bit torque, 14-bit speed or equivalent
(Output) 10-bit or equivalent × 2ch
SSCNET III Interface
(Output) 10-bit or equivalent × 2ch
5 - 2
MR-J4 series
(100 V class) 0.1 kW to 0.4 kW
(200 V class) 0.1 kW to 22 kW
(400 V class) 0.6 kW to 22 kW
Built-in (0.2 kW to 7 kW)
External (11 kW to 22 kW)
Built-in (0.1 kW to 7 kW)
External (11 kW to 22 kW)
Coasting distance is different. (Note1)
(100 V class)
1-phase 100V AC to 120V AC
(200 V class)
1-phase 200V AC to 240V AC
(400 V class)
1-phase 380V AC to 480V AC
(100 V class)
1-phase 100V AC to 120V AC
(200 V class)
1-phase 200V AC to 240V AC (0.1 kW to 2 kW)
3-phase 200V AC to 240V AC (0.1 kW to 22 kW)
(400 V class)
3-phase 380V AC to 480V AC
External supply required
Real-time auto tuning: 40 steps
One-touch tuning
General-Purpose Interface
Position control mode (pulse command)
Speed control mode (analog command)
Torque control mode (analog command)
SSCNET III/H Interface (150 Mbps)
Position control mode
Speed control mode
Torque control mode
<
>
J3 compatibility mode
SSCNET III/H Interface (50 Mbps)
Position control mode
Speed control mode
Differential pulse: 4 Mpulses/s
Command pulse: Sink
General-Purpose Interface
DI: 9 points, DO: 6 points
SSCNET III/H Interface
DI: 3 points, DO: 3 points
ABZ-phase (differential line driver)
General-Purpose Interface
Z-phase (open collector)
input/output: sink/source
General-Purpose Interface
(Input) 2ch
10-bit torque, 14-bit speed or equivalent
(Output) 10-bit or equivalent × 2ch
SSCNET III/H Interface
(Output) 10-bit or equivalent × 2ch