Part 2: Review on Replacement of MR-J3-_A_ with MR-J4-_A_
MR-J3-_A_
No.
Name and function
PA15
Encoder output pulse
Turn off the power and then on again after setting
the parameter to validate the parameter value.
Used to set the encoder pulses (A-phase, B-phase)
output by the servo amplifier.
You can use parameter [Pr. PC19] to choose the
output pulse setting or output division ratio setting.
The number of A/B-phase pulses actually output is
1/4 times greater than the preset number of pulses.
The maximum output frequency is 4.6 Mpulses/s
(after multiplication by 4). Use this parameter within
this range.
(1) For output pulse designation
Set "_ _ 0 _" (initial value) in [Pr. PC19].
Set the number of pulses per servo motor
revolution.
Output pulse = set value [pulses/rev]
For instance, set "5600" to [Pr. PA15], the
actually output A/B-phase pulses are as
indicated below.
A/B-phase output pulses
(2) For output division ratio setting
Set "0 0 1 0" in parameter [Pr. PC19]
The number of pulses per servo motor revolution
is divided by the set value.
Resolution per servo motor revolution
Output pulse
For instance, set "8" to [Pr. PA15], the actually
A/B-phase pulses output are as indicated below.
A/B-phase output pulses
(3) When outputting pulse train similar to command
pulses
Set [Pr. PC19] to "_ _ 2 _". The feedback pulses
from the servo motor encoder are processed and
output as shown below. The feedback pulses can
be output in the same pulse unit as the command
pulses.
Feedback pulse
Parameter No.PA05
"0"(Initial value)
FBP
Pt
Other than "0"
Initial
value
4000
5600
1400 [pulse]
4
[pulses/rev]
Set value
262144
1
8192 [pulse
8
4
Servo motor
M
Encoder
Parameter No.PA06, PA07
CDV
CMX
A/B-phase output pulses
MR-J4-_A_
No.
Name and function
PA15
Set the encoder output pulses from the servo
amplifier by using the number of output pulses per
revolution, dividing ratio, or electronic gear ratio.
(after multiplication by 4)
To set a numerator of the electronic gear, select "A-
phase/B-phase pulse electronic gear setting (_ _ 3
_)" of "Encoder output pulse setting selection" in [Pr.
PC19].
The maximum output frequency is 4.6 Mpps (after
multiplication by 4). Use this parameter within this
range.
Setting range: 1 to 4194304
PA16
Set a denominator of the electronic gear for the A/B-
phase pulse output.
To set a denominator of the electronic gear, select
"A-phase/B-phase pulse electronic gear setting (_ _
3 _)" of "Encoder output pulse setting selection" in
[Pr. PC19].
Setting range: 1 to 4194304
2 - 28
Control
Initial
mode
value
4000
P
S
T
1
P
S
T