Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
No.
Name and function
PD31
Master-slave operation - Speed limit coefficient on slave
This parameter setting is used with servo amplifier with
software version C1 or later. Check the software version
using Setup software (SETUP221E).
This parameter is used to set an internal speed limit
value coefficient to speed limit command value received
from master axis. This parameter is enabled when this
amplifier is set as slave axis ([Pr. PD15] = "0010").
Convert a decimal value to a hexadecimal value for
input. The maximum value is 500. Setting over 500 will
be 500.
Setting 100 [%] (0064h in hexadecimal) means
multiplication of one.
Setting example: [Pr. PD31 (VLC)] = 0078h (120%), [Pr.
PD32 (VLL)] = 012Ch (300 r/min), and master side
acceleration/deceleration at 1000 [r/min]
Speed command
from master side
VLL
300r/min
0
PD32
Master-slave operation - Speed limit adjusted value on
slave
This parameter setting is used with servo amplifier with
software version C1 or later. Check the software version
using Setup software (SETUP221E).
This parameter is used to set a minimum value for
internal speed limit value.
This parameter is enabled when this amplifier is set as
slave axis ([Pr. PD15] = "0010"). Convert a decimal value
to a hexadecimal value for input. The speed limit value
will not be this setting value or lower.
This parameter ensures torque control range at low
speed driving (avoid area likely to reach speed limit). Set
100 to 500 [r/min] normally as a reference.
Refer to [Pr. PD31] for the setting example.
MR-J3-_B_
Speed limit value of
slave side
1200r/min
1000r/min
Speed limit command
from master side (driver
communication)
Initial
No.
value
0000h
PD31
Master-slave operation - Speed limit coefficient on slave
This parameter is used to set an internal speed limit
value coefficient to speed limit command value received
from master axis.
This parameter is enabled when this amplifier is set as
slave axis ([Pr. PD15] is "_ _ 1 0".). The maximum value
is 500. Setting over 500 will be 500.
Setting 100 [%] means multiplication of one.
Setting example: [Pr. PD31 (VLC)] = 140 [%], [Pr. PD32
(VLL)] = 300 [r/min], and master side
acceleration/deceleration at 1000 [r/min]
Speed command from
master side × VLC [%]
VLL
300 r/min
0
This parameter setting is used with servo amplifier with
software version A8 or later.
0000h
PD32
Master-slave operation - Speed limit adjusted value on
slave
This parameter is used to set a minimum value for
internal speed limit value.
This parameter is enabled when this amplifier is set as
slave axis ([Pr. PD15] is "_ _ 1 0".). The speed limit value
will not be this setting value or lower.
This parameter ensures torque control range at low
speed driving (avoid area likely to reach speed limit). Set
100 to 500 [r/min] normally as a reference.
Refer to [Pr. PD31] for the setting example.
This parameter setting is used with servo amplifier with
software version A8 or later.
3 - 48
MR-J4-_B_
Name and function
Speed limit value of
slave side
1400 r/min
1000 r/min
Speed limit command
from master side (driver
communication)
Initial
value
0