Mitsubishi Electric MELSERVO-J3 Series Manual page 346

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 5: Common Reference Material
3) MBR (Electromagnetic brake interlock) will turn off when [AL. 10.1 Voltage drop in the control
circuit power] occurs.
(b) Requirements conditions of SEMI-F47 standard
Table 5.9 shows the permissible time of instantaneous power failure for instantaneous power failure
of SEMI-F47 standard.
(c) Calculation of tolerance against instantaneous power failure
Table 5.10 shows tolerance against instantaneous power failure when instantaneous power failure
voltage is "rated voltage × 50%" and instantaneous power failure time is 200 ms.
Table 5.9 Requirements conditions of SEMI-F47 standard
Instantaneous power
failure voltage
Rated voltage × 80%
Rated voltage × 70%
Rated voltage × 50%
Table 5.10 Tolerance against instantaneous power failure
(instantaneous power failure voltage = rated voltage × 50%,
instantaneous power failure time = 200 ms)
Servo amplifier
MR-J4-10B(-RJ)
MR-J4-20B(-RJ)
MR-J4-40B(-RJ)
MR-J4-60B(-RJ)
MR-J4-70B(-RJ)
MR-J4-100B(-RJ)
MR-J4-200B(-RJ)
MR-J4-350B(-RJ)
MR-J4-500B(-RJ)
MR-J4-700B(-RJ)
MR-J4-11KB(-RJ)
MR-J4-15KB(-RJ)
MR-J4-22KB(-RJ)
MR-J4-60B4(-RJ)
MR-J4-100B4(-RJ)
MR-J4-200B4(-RJ)
MR-J4-350B4(-RJ)
MR-J4-500B4(-RJ)
MR-J4-700B4(-RJ)
MR-J4-11KB4(-RJ)
MR-J4-15KB4(-RJ)
MR-J4-22KB4(-RJ)
MR-J4W2-22B
MR-J4W2-44B
MR-J4W2-77B
MR-J4W2-1010B
Permissible time of
instantaneous power failure [s]
1
0.5
0.2
Instantaneous maximum
output [W]
350
700
1400
2100
2625
3000
5400
10500
15000
21000
40000
50000
56000
1900
3500
5400
10500
15000
21000
40000
50000
56000
1400 (700 × 2)
2800 (1400 × 2)
5250 (2625 × 2)
6000 (3000 × 2)
5 - 161
Tolerance against instantaneous
power failure [W]
(voltage drop between lines)
250
420
630
410
1150
1190
2040
2600
4100
5900
2600
3500
4300
190
200
350
730
890
1500
2400
3200
4200
790
1190
2300
2400

Hide quick links: