Mitsubishi Electric MELSERVO-J3 Series Manual page 133

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 3: Review on Replacement of MR-J3-_B_ with MR-J4-_B_
No.
Name and function
PC20
Function Selection C-7
Set this function if undervoltage alarm occurs because of
distorted power supply voltage waveform when using
power regenerative converter or power regeneration
common converter.
0 0 0 x:
Setting when undervoltage alarm occurs
0: Initial value (Waveform of power supply voltage is not
distorted)
1: Set "1" if undervoltage alarm occurs because of
distorted power supply voltage waveform when using
power regenerative converter or power regeneration
common converter.
PC21
Alarm history clear
Used to clear the alarm history.
0 0 0 x:
Alarm history clear
0: Invalid
1: Valid
When alarm history clear is made valid, the alarm history
is cleared at next power-on.
After the alarm history is cleared, the setting is
automatically made invalid (reset to 0).
MR-J3-_B_
Initial
No.
value
0000h
PC20
Function selection C-7
This is used to select an undervoltage alarm detection
method.
_ _ _ x:
[AL. 10 Undervoltage] detection method selection
This is set when FR-RC-(H) or FR-CV-(H) is used and if
[AL. 10 undervoltage] occurs due to distorted power
supply voltage waveform.
0: [AL. 10] not occurrence
1: [AL. 10] occurrence
_ _ x _ :
For manufacturer setting
_ x _ _ :
Undervoltage alarm selection
Select the alarm and warning for when the bus voltage
drops to the undervoltage alarm level.
0: [AL. 10] regardless of servo motor speed
1: [AL. E9] at servo motor speed 50 r/min (50 mm/s) or
less, [AL. 10] at over 50 r/min (50 mm/s)
x _ _ _ :
For manufacturer setting
0000h
PC21
Same as MR-J3
Alarm history clear
Used to clear the alarm history.
_ _ _ x:
Alarm history clear selection
0: Disabled
1: Enabled
When "Enabled" is set, the alarm history will be cleared
at the next power-on. After the alarm history is cleared,
the setting is automatically disabled.
_ _ x _ :
For manufacturer setting
_ x _ _ :
For manufacturer setting
x _ _ _ :
For manufacturer setting
3 - 40
MR-J4-_B_
Name and function
Initial
value
0h
0h
0h
0h
0h
0h
0h
0h