Mitsubishi Electric MELSERVO-J3 Series Manual page 228

Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

Part 5: Common Reference Material
No.
Name
PC02 Deceleration time constant
S-pattern acceleration/deceleration
PC03
time constant
PC04 Torque command time constant
Internal speed command 1
PC05
Internal speed limit 1
Internal speed command 2
PC06
Internal speed limit 2
Internal speed command 3
PC07
Internal speed limit 3
Internal speed command 4
PC08
Internal speed limit 4
Internal speed command 5
PC09
Internal speed limit 5
Internal speed command 6
PC10
Internal speed limit 6
Internal speed command 7
PC11
Internal speed limit 7
Analog speed command maximum
PC12
speed
Analog speed limit maximum speed
Analog torque command maximum
PC13
output
PC14 Analog monitor 1 output
PC15 Analog monitor 2 output
Electromagnetic brake sequence
PC16
output
PC17 Zero speed
PC18 Alarm history clear
PC19 Encoder output pulses selection
PC20 Station number setting
PC21 Communication function selection
PC22 Function selection C-1
PC23 Function selection C-2
PC24 Function selection C-3
PC26 Function selection C-5
PC27 Function selection C-6
PC30 Acceleration time constant 2
PC31 Deceleration time constant 2
Command pulse multiplying factor
PC32
numerator 2
Command pulse multiplying factor
PC33
numerator 3
Command pulse multiplying factor
PC34
numerator 4
PC35 Internal torque limit 2
PC36 Status display selection
MR-J3-_A_
Type
Dec
Dec
Dec
Dec
Dec
Dec
Dec
Dec
Dec
Dec
Dec
Dec
Hex
Hex
Dec
Dec
Hex
Hex
Dec
Hex
Hex
Hex
Hex
Hex
Hex
Dec
Dec
Dec
Dec
Dec
Dec
Hex
MR-J4-_A_
Target
No.
Type
-
PC02
Dec
-
PC03
Dec
-
PC04
Dec
-
PC05
Dec
-
PC06
Dec
-
PC07
Dec
-
PC08
Dec
-
PC09
Dec
-
PC10
Dec
-
PC11
Dec
-
PC12
Dec
-
PC13
Dec
_ _ XX
PC14
Hex
_ _ XX
PC15
Hex
-
PC16
Dec
-
PC17
Dec
_ _ _ X
PC18
Hex
_ _ XX
PC19
Hex
-
PC20
Dec
_ XX_
PC21
Hex
X_ _ _
PC22
Hex
_ _ _ X
PC23
Hex
XX_ _
_ _ _ X
PC24
Hex
_ _ _ X
PC26
Hex
_ _ _ X
PC27
Hex
-
PC30
Dec
-
PC31
Dec
-
PC32
Dec
-
PC33
Dec
-
PC34
Dec
-
PC35
Dec
_ _ XX
PC36
Hex
_ X_ _
Hex: hexadecimal parameter; Dec: decimal parameter
5 - 43
Conversion rule
Target
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
_ _ XX
The setting value will be maintained.
_ _ XX
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
_ _ _ X
The setting value will be maintained.
_ _ XX
The setting value will be maintained.
-
The setting value will be maintained.
_ XX_
The setting value will be maintained.
X_ _ _
The setting value will be maintained.
_ _ _ X
The setting value will be maintained.
XX_ _
The setting value will be maintained.
_ _ _ X
The setting value will be maintained.
_ _ _ X
The setting value will be maintained.
_ _ _ X
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
The setting value will be maintained.
-
The setting value will be maintained.
-
The setting value will be maintained.
-
-
The setting value will be maintained.
_ _1_ will be changed to _ _ 00.
_ _ XX
Otherwise, the setting value will be
maintained.
_ X_ _
The setting value will be maintained.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents