Figure 70: Hard Drive Removal - Tekelec 1100 Hardware Manual

Application server
Hide thumbs Also See for 1100:
Table of Contents

Advertisement

Hardware Manual
assembly from the failed chassis and replace it into the "B" position of the replacement
chassis.
WARNING: When replacing both drives in a failedT1100 AS chassis always place
the drives in the locations they were removed from. Failure to replace the drives
in the correct locations will cause data corruption and render the unit inoperable.
6. Insert your index finger into the right side of the drive release latch.
Pull the latch towards you to disengage the drive and pull the drive out of the chassis.

Figure 70: Hard drive removal

7. Remove the hard disk drive and store in an approved ESD package or place on a grounded
bench.
8. Do one of the following:
a) If this procedure is being performed to replace a failed hard disk drive, note the position
label attached to the failed hard disk drive assembly.
Select the matching label ("A" or "B") from the contents of the shipping container in which
the replacement hard disk drive assembly was received, and apply it to the hard disk drive.
Figure 73: Disk Drive label locations (fans removed)
be applied
b) If this procedure is being performed to move hard disk drive assemblies from a failedT1100
AS chassis to the replacementT1100 AS chassis, locate the part numbers on each of the hard
disk drive assemblies (see
Ensure that the part numbers on hard disk drive assemblies to be moved match the part
numbers for both the A and B positions on the base unit/hard disk label on the front of the
left side of the replacementT1100 AS chassis (see
910-2969-001 Revision K, June 2009
on page 122 shows where the labels should
Figure 73: Disk Drive label locations (fans removed)
Figure 71: T1100 AS Chassis Label Locations
Field Replaceable Units
on page 122).
121