Serial Communication - Tekelec 1100 Hardware Manual

Application server
Hide thumbs Also See for 1100:
Table of Contents

Advertisement

Hardware Manual
Interface
IP Port
5019
9696
1030
7483
9691
1. FTP data is normally received from the customer's Provisioning System. This assumes the
firewall automatically opens the high numbered return port (the default behavior of firewalls
like Firewall-1). If using a basic packet filtering router, contact the
7.
2. The two-way TCP communication channel endpoints are the port number 22 and the Server
spawned random port value.
3. These ports are configurable via the configuration menus of the ELAP and EPAP software. See
Configuration Menu" in the ELAP Administration Manual or EPAP Administration Manual for
more information.

Serial Communication

Each MPS server has two onboard serial ports. Serial port A is the Console port and serial port
B is connected by a null-modem cable to serial port A on the mate
MPS server. The lower ELAP or EPAP server is configured with an additional 8 serial ports in a
multiport PCI serial port card.
910-2969-001 Revision K, June 2009
Use
Versant Fault
Tolerant
Server - EPAP
database
mgmt system
PDBA - PDB
application
messages the
provisioning
data
3
LSMS Bulk
Download and
High Speed
Audit
3
LSMS
Provisioning
Data
Watcher Port
(diagnostics)
ELAP or EPAP Network Integration
In
Out
bound
bound
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Customer Care Center
MPS
Application
EPAP only
EPAP only
ELAP only
ELAP only
ELAP only
on page
153

Advertisement